II - 5
The locking boss on the side sensor holder 24B enters the locking boss hole on the
tape cassette, and the side sensor switches are held down according to the holes on
the tape cassette. (The side sensor turns ON when the sensor switches that
correspond to the sections without holes are held down.)
The tape cassette type and width are determined depending on the pattern that the
side sensor switches are held down. (The tape cassette type and width are
determined depending on the holes (1 to 5) at the section "A".)
Figure 2.1-5 Side Sensor Mechanism
Tape cassette
Locking boss hole Locking boss
"A"
Side sensor PCB ASSY
Side sensor
switches (5 pcs.)
Side sensor hole
Side
sensor
holder 24B
Side sensor
PCB ASSY
Summary of Contents for P-touch PT-D600
Page 1: ...SERVICE MANUAL MODEL PT D600 ...
Page 171: ...Oct 2014 SM PT079 1 ...