IV - 84
[ 5 ] Tape cassette type not identified
N
N
Y
Y
The tape cassette type
cannot be identified correctly.
Correct them with
lead-free solder.
The side sensor PCB is
defective. Replace it.
- Select “Head Rank” in the Factory
Inspection mode.
- Regulate the motor speed in PRINT1
submode.
Enter the inspection mode (see Section 3.2)
and do the following for the new main PCB
ASSY:
Replace the main PCB ASSY.
Does each sensor
actuator on the side sensor
PCB work normally?
Are the
cassette sensor leads
soldered correctly?