App. 1-38
Confidential
<WSW38> (V.34 transmission settings)
• Selectors 1 and 2: Setting of the equalizer
These selectors set the equalizer's training level to be applied if the machine fails to send
training due to weak line connection. If these selectors are set to "0, X," the modem will
automatically set the appropriate training level.
• Selector 3: Sending level of guard tone at phase 2
This selector sets the sending level of guard tone for 1800 Hz to be sent at Phase 2 in the
V. 34 mode.
• Selector 4: Stepping down the transmission speed at fallback each
This selector determines how much the modem steps down the transmission speed at
fallback when called by the remote station. If this selector is set to "1," the modem may
step down the transmission speed from 33600 bps to 28800 bps by one-time fallback.
• Selectors 5 and 6: Automatic control of modem's EQM gain for proper transmission speed choice
These selectors determine how the modem controls the EQM (Eye Quality Monitor) gain
for proper choice of the transmission speed, which applies if the modem selects higher
transmission speed than the possible speed so that it always repeats falling back.
• Selector 8: Detection of CED for stopping CNG
If this selector is set to "0," the detection time of CED specified by WSW43, selectors 4 and
5 will apply.
Selector No.
Function
Setting and Specifications
1
2
Setting of the equalizer
No. 1 2
0 0: Automatic
0 1: Automatic
1 0: Fixed to 4 points
1 1: Fixed to 16 points
3
Sending level of guard tone at
phase 2
0: Normal - 7 db 1: Normal
4
Stepping down the transmission
speed at fallback each
0: 2,400 bps
1: 4,800 bps
5
6
Automatic control of modem's
EQM gain for proper
transmission speed choice
No. 5 6
0 0: For higher transmission speed
than the current setting
0 1: No change from the current
setting
1 0: For lower transmission speed
than the current setting
1 1: For further lower transmission
than the setting made by 1, 0
7
Redialing when a communications
error occurs
0: ON
1: OFF
8
Detection of CED for stopping CNG
0: ON
1: OFF
Summary of Contents for DCP 8085DN
Page 13: ...CHAPTER 1 SPECIFICATIONS ...
Page 52: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Page 69: ...2 16 Confidential 3 3 Paper Feeding Fig 2 18 LT path DX path MP path Paper tray path ...
Page 89: ...CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Page 178: ...Confidential CHAPTER 4 PERIODICAL MAINTENANCE ...
Page 248: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Page 265: ...5 12 Confidential Fig 5 7 EM2 4 places Separation pad ASSY ...
Page 501: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 507: ...6 5 Confidential 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 516: ...CHAPTER 7 SERVICE MODE ...
Page 525: ...7 7 Confidential For color scanning Fig 7 2 ...
Page 527: ...7 9 Confidential For white and black scanning Fig 7 3 ...
Page 528: ...7 10 Confidential For color scanning Fig 7 4 ...
Page 567: ...Confidential CHAPTER 8 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 569: ...8 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram Fig 8 1 ...
Page 570: ...8 2 Confidential LVPS PCB Circuit Diagram 230V Fig 8 2 ...
Page 571: ...8 3 Confidential LVPS PCB Circuit Diagram 115V Fig 8 3 ...