App.
4-3
Confidential
WSW01
(Dial pulse setting)
Selector
No.
Function
Setting and Specifications
1
2
Dial pulse generation mode
No. 1 2
0
0
: N
0
1
: N+1
1
0
: 10-N
1
1
: N
3
4
Break time length in pulse dialing
No. 3 4
0
0
: 60
ms
0
1
: 67
ms
1 0
:
40 ms (for 16 PPS)
1 1
:
64 ms (at 106-ms intervals)
5
6
Inter-digit pause
No. 5 6
0
0
: 800
ms
0
1
: 850
ms
1
0
: 950
ms
1
1
: 600
ms
7
Switching between pulse (DP) and
tone (PB) dialing, by the function
switch
0:
Yes
1:
No
8
Default dialing mode, pulse (DP)
or tone (PB) dialing
0:
PB
1:
DP
Selectors 1 and 2: Dial pulse generation mode
These selectors set the number of pulses to be generated in pulse dialing.
N:
Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)
N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.
Selectors 3 and 4: Break time length in pulse dialing
These selectors set the break time length in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)
Selectors 5 and 6: Inter-digit pause
These selectors set the inter-digit pause in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...