Confidential
9-11
9.1.2 Communications
Errors
If a communications error occurs, the facsimile equipment
(1) emits an audible alarm (intermittent beeping) for approximately 4 seconds,
(2) displays the corresponding error message, and
(3) prints out the transmission verification report if the equipment is in sending operation.
Definition of error codes on the communications list
(1) Calling
Code 1
Code 2
Causes
10
08
Wrong number called.
11
01
No dial tone detected before start of dialing.
11
02
Busy tone detected before dialing.
11
03
2nd dial tone not detected.
11
05
No loop current detected. *
11
06
Busy tone detected after dialing or called.
11
07
No response from the remote station in sending.
11
10
Unobtainable tone detected after dialing.
17
07
No response from the calling station in receiving.
* Available in German models only.
(2) Command
reception
Code 1
Code 2
Causes
20
01
Unable to detect a flag field.
20
02
Carrier was OFF for 200 ms or longer.
20
03
Abort detected ("1" in succession for 7 bits or more).
20 04
Overrun
detected.
20
05
A frame for 3 seconds or more received.
20
06
CRC error in answerback.
20
07
Error command received.
20
08
Invalid command received.
20
09
Command ignored once for document setting or for dumping-out
at turn-around transmission.
20
0A
T5 time-out error
20 0B
CRP
received.
20
0C
EOR and NULL received.
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...