Confidential
5 -4 6
(10) Remove the HR gear.
(11) Remove the two HR bush.
(12) Remove the thermistor ASSY harness from the four hooks.
(13) Remove the cup B M3x12 taptite screw, and then remove the thermistor ASSY.
Heat roller
HR bush
Hooks
HR bush
HR gear
Return the hook to the
original position.
HR gear
Return the hook to the
original position.
Thermistor ASSY
Taptite, cup B M3x12
Hooks
Hooks
Fuser frame
Thermistor ASSY harness
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...