Confidential
5 -1
5.1 DISASSEMBLY/REASSEMBLY
Safety Precautions
To prevent the creation of secondary problems by mishandling, observe the following
precautions during maintenance work.
(1) Before starting disassembly/reassembly jobs, unplug the power cord and telephone line.
In particular, when having access to the power supply inside the machine, make sure that
the power cord is unplugged from the electrical outlet; when having access to the main
PCB or NCU PCB, make sure that both the power cord and telephone line are unplugged
from the machine.
(2) Be careful not to lose screws, washers, or other parts removed for parts replacement.
(3) When using soldering irons and other heat-generating tools, take care not to damage the
resin parts such as wires, PCBs, and covers.
(4) Static electricity charged in your body may damage electronic parts.
Before handling the PCBs, touch a metal portion of the machine to discharge static
electricity charged in your body. When transporting PCBs, be sure to wrap them in
conductive sheets such as aluminum foil.
(5) Be sure to reinsert self-tapping screws correctly, if removed.
(6) Tighten screws to the torque values listed on the next page.
(7) When connecting or disconnecting cable connectors, hold the connector bodies not the
wires. If the connector has a lock, always slide the connector lock to unlock it.
(8) Before reassembly, apply the specified lubricant to the specified points.
(Refer to
Section 5.2
in this chapter.)
(9) After repairs, check not only the repaired portion but also that the connectors and other
related portions function properly before operation checks.
(10) After you use the machine, some internal parts are extremely HOT! To prevent injuries,
be careful not to put your fingers in the areas shown in the illustration.
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...