8 - 5
Confidential
8.4 DETAILED DESCRIPTION OF
MAINTENANCE-MODE FUNCTIONS
8.4.1 EEPROM Parameter Initialization (Function code 01/91)
Function
The machine initializes the parameters, user switches, and firmware switches registered in
the EEPROM, to the initial values. Entering the function code 01 initializes all of
the EEPROM areas, but entering 91 does not initialize some areas, as listed below.
Function code
Data item
01 91
Maintenance-mode functions
User switches
Firmware switches
These will be
initialized.
Remote activation code
These will not be
initialized.
Station ID data
Outside line number
Telephone function registration
One-touch dialing
Speed dialing
Group dialing
All of these will be
initialized.
These will not be
initialized.
NOTE:
If you replace the main PCB with the one used for any other machine, carry out this
procedure and then customize the EEPROM (maintenance-mode function code 74 in
Section 8.4.14
).
Operating
Procedure
(1) MFC7420/7820N
Press the
0
and
1
keys (or the
9
and
1
keys according to your need) in this order in the
initial stage of the maintenance mode.
DCP7010/7020/7025
Press the key or key several times to display the “MAINTENANCE 01” or
“MAINTENANCE 91” code on the LCD. Then press the
Set
key
.
The "PARAMETER INIT" will appear on the LCD.
(2) Upon completion of parameter initialization, the machine returns to the initial stage of
the maintenance mode.
(3) Be sure to turn the machine power off. If you press the
9
key twice to exit from the
maintenance mode without turning the power off, then the machine will not fully
initialize the EEPROM.
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...