App.
4-18
Confidential
WSW14
(AUTO ANS facility setting)
Selector
No.
Function
Setting and Specifications
1
2
Frequency band selection (lower
limit) for incoming calling signal
(CI)
No. 1 2
0 0 : 13
Hz
0 1 : 15
Hz
1 0 : 23
Hz
1 1 : 20
Hz
3
4
Frequency band selection (upper
limit) for incoming calling signal
(CI)
No. 3 4
0 0 : 30
Hz
0 1 : 55
Hz
1 0 : 70
Hz
1 1 : 200
Hz
5
|
8
No. of rings in AUTO ANS mode
No. 5 6 7 8
0 0 0 0 : Fixed
to
once
0 0 0 1 : Fixed
to
2
times
0 0 1 0 : Fixed
to
3
times
0 0 1 1 : Fixed
to
4
times
0 1 0 0 : 1
to
2
times
0 1 0 1 : 1
to
3
times
0 1 1 0 : 1
to
4
times
0 1 1 1 : 1
to
5
times
1 0 0 0 : 2
to
3
times
1 0 0 1 : 2
to
4
times
1 0 1 0 : 2
to
5
times
1 0 1 1 : 2
to
6
times
1 1 0 0 : 1
to
10
times
1 1 0 1 : 2
to
10
times
1 1 1 0 : 3
to
5
times
1 1 1 1 : 4
to
10
times
Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting made by
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even
if the setting made by these selectors does not apply, it will be printed on the configuration list.)
Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...