App.
4-14
Confidential
WSW10
(Protocol definition 2)
Selector
No.
Function
Setting and Specifications
1 Not
used.
2
Time length from transmission
of the last dial digit to CML
ON
0: 100 ms
1: 50 ms
3
Time length from CML ON to
CNG transmission
0: 2 sec.
1: 4 sec.
4
Time length from CML ON to
CED transmission (except for
facsimile-to-telephone
switching)
0: 0.5 sec.
1: 2 sec.
5
6
No. of training retries
No. 5 6
0
0
:
1
time
0
1
:
2
times
1
0
:
3
times
1
1
:
4
times
7
MR 0:
Allowed
1:
Not
allowed
8
Encoding system
(Compression)
MMR 0:
Allowed 1:
Not
allowed
Selector 2: Time length from transmission of the last dial digit to CML ON
This selector sets the time length from when the machine transmits the last dial digit until the CML
relay comes on.
Selector 3: Time length from CML ON to CNG transmission
This selector sets the time length until the machine transmits a CNG after it turns on the CML
relay.
Selector 4: Time length from CML ON to CED transmission
This selector sets the time length until the machine transmits a CED after it turns on the CML
relay. This setting does not apply to switching between facsimile and telephone.
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
Selectors 7 and 8: Encoding system (Compression)
This selector determines whether or not to allow the use of the MR/MMR coding system.
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...