Confidential
9-23
M-5
Insufficient output from high-voltage power supply unit
Possible cause
Step
Check
Result
Remedy
High-voltage
contact
1
Do any of the terminals on
the high-voltage contacts
have dirt or contact burns?
Yes Clean the terminals.
Yes Replace the high-voltage power
supply PCB.
High-voltage
power supply
PCB
2
Check the connections of
the connector between the
high-voltage power supply
and the main PCB are
secured correctly?
No
Reconnect the connector
between the high-voltage power
supply and the main PCB.
M-6
Fixing heater temperature failure
Possible cause
Step
Check
Result
Remedy
Poor
thermistor
harness
contact
1
Is the contact of connector
CN19 on the main PCB
good?
No
Reconnect the connector.
Blown thermal
fuse
2
Remove the fixing unit and
measure the resistance of
the thermal fuse. Is it open
circuit?
Yes Replace the fixing unit.
Blown
thermostat
3
Remove the fixing unit and
measure the resistance of
the thermostat. Is it open
circuit?
Yes Replace the fixing unit.
Halogen
heater lamp
failure
4
Remove the fixing unit and
measure the resistance of
the halogen heater lamp. Is
it open circuit?
Yes Replace the halogen heater
lamp.
M-7
Laser Unit failure
Possible cause
Step
Check
Result
Remedy
No
Reconnect the connector
securely.
Harness
connection
failure (1)
1
Is connector CN6 on the
main PCB secured
correctly?
Yes Replace the laser unit.
No
Reconnect the connector
securely.
Harness
connection
failure (2)
2
Is the connection of the
scanner motor connector
CN6 on the main PCB
secure?
Yes Replace the laser unit.
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...