Confidential
9-21
[ 3 ] Malfunction
When taking countermeasures for malfunctions as described in this section, check connectors for
contact failure before measuring the voltage at the specified connector pins.
M-1
No AC power supplied
Possible cause
Step
Check
Result
Remedy
Supply
voltage
1
Is the correct voltage
present at the outlet?
No
Inform the user that the correct
voltage is not supplied at the
outlet.
Power plug
2
Is the power cord securely
plugged into the outlet?
No
Plug the power cord securely
into the outlet.
Fuse (F1, F2)
3
Is the fuse blown?
Yes If the fuse blows again
immediately after replacing the
low-voltage power supply PCB,
check that there is not a short
circuit somewhere in the AC
power supply line.
Wiring
4
Unplug the power supply
plug. Is there a broken
wire between the AC input
connector of the low-
voltage power supply and
the power plug?
Yes Replace the AC power cord.
M-2
No DC power supplied
Possible cause
Step
Check
Result
Remedy
AC power
supply
1
Is AC power supplied
between connectors CN1-L
and CN1-N when the
power plug is plugged into
the outlet?
No
Follow the same check
procedure of M-1 “No AC
power supplied”.
Wiring, DC
load
2
Turn on the power switch.
Measure the voltages
between the terminals. Do
the measured voltage
satisfy the prescribed
valued in the table below?
Yes Turn off the power switch,
reconnect the connector and
turn the power switch on again.
If the protector circuit is
activated, check the connector,
the wiring from the connector,
and the DC load.
Low-voltage
power supply
PCB
3
Refer to the chart * 1
below.
No
Replace the low-voltage power
supply PCB.
*1
PCB
+lead pin
- lead pin
Voltage
Main CN12-6
CN12-8
CN12-9
CN12-9
Approx. 24V
Approx. 5V
Summary of Contents for DCP-7010
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Page 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 64: ......
Page 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 68: ...Confidential 4 2 Cover page sample End page sample ...
Page 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 154: ...Confidential CHAPTER 7 CLEANING ...
Page 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 172: ...8 15 Confidential Configuration List ...
Page 178: ...8 21 Confidential Cover page sample End page sample ...
Page 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Page 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Page 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Page 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Page 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Page 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Page 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...