2-86
Confidential
Dark
Poor fixing
<User Check>
• Check the usage environment of the machine. Using the machine in
hot-humid or cold-dry conditions can cause this problem.
• If a new toner cartridge has been detected, check that it was not
replaced with another toner cartridge.
• Execute density adjustment from the control panel.
• Clean the corona wire of the drum unit.
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
Dirt on the electrodes of the
drum unit and those of the
machine
Clean the electrodes of the drum unit and
those of the machine. (Refer to
.)
2
Wrong adjusted value of the
laser unit entered
Refer to
“3.1 Entering Adjusted Value of
, and enter the
adjusted value of the laser unit correctly.
3
Dirt on the electrodes of the
high-voltage power supply PCB
Clean the electrodes of the high-voltage
power supply PCB.
4
Fuser unit failure
Replace the fuser unit.
5
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
6
Laser unit failure
Replace the laser unit.
7
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Check the usage environment of the machine. Using the machine in
hot-humid or cold-dry conditions can cause this problem.
• Clean the corona wire of the drum unit.
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
Dirt on the electrodes of the
drum unit and those of the
machine
Clean the electrodes of the drum unit and
those of the machine. (Refer to
.)
2
Dirt on the electrodes of the
toner cartridge and those of
the machine
Clean the electrodes of the toner cartridge
and those of the machine. (Refer to
and
.)
3
Fuser unit failure
Replace the fuser unit.
4
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
5
Low-voltage power supply
PCB failure
Replace the low-voltage power supply PCB
ASSY.
6
Laser unit failure
Replace the laser unit.
7
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...