3-80
Confidential
MP models
(1) Disconnect the MP relay flat cable from the Main PCB ASSY.
(2) Release the MP sensor harness and the MP paper empty sensor harness from the
securing fixtures.
(3) Remove the Taptite bind B M4x12 screw. Remove the MP relay PCB ASSY, and
disconnect each harness from the MP relay PCB ASSY.
Fig. 3-75
Harness routing: Refer to
,
“11. Frame L unit (MP models)”
.
Assembling Note:
• Secure each harness in the Hooks in order of the Hook A to E, and then secure
them in the Hooks from the Hook F to G. Be sure to give them enough slack in the
H part for adjustment.
Taptite bind B M4x12
MP relay PCB ASSY
MP relay flat
cable
Main PCB ASSY
MP sensor harness
MP paper empty sensor harness
MP relay flat cable
Hook B
Hook D
Hook C
Hook F
Hook E
Hook A
H part
Hook G
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...