2-66
Confidential
Error code A400
The ADF cover sensor detected that the ADF cover was open.
<User Check>
• Close the ADF cover correctly.
Error code A500
When scanning the fax, white or black correction data for the first side CIS unit was not within
the correct range (first time).
Error code A600
When scanning the fax, white or black correction data for the first side CIS unit was not within
the correct range (second time).
Step
Cause
Remedy
1
ADF cover actuator caught in
some sections of the machine
Reattach the ADF cover actuator.
2
ADF cove sensor attachment
failure
Reattach the ADF cover sensor.
3
ADF cover attachment failure
Reattach the ADF cover.
4
Connection failure of the ADF
cover sensor harness
Reconnect the ADF cover sensor
harness.
5
Damaged ADF cover
Replace the ADF cover.
6
ADF cover sensor failure
Replace the ADF unit.
7
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Incorrect correction data for first
side CIS unit
Execute “Acquire white level data
2
Dirt on the white tape on the
second side document hold
Clean the white tape on the second side
document hold.
3
Damaged first side CIS flat cable
Replace the first side CIS flat cable.
4
First side CIS unit failure
Replace the first side CIS unit.
5
White tape failure
Replace the document scanner unit.
6
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...