3-75
Confidential
9.20 New toner sensor PCB ASSY
(1) Disconnect the New toner sensor flat cable from the High-voltage power supply PCB
ASSY, and release the Hook to remove the New toner sensor PCB ASSY. Disconnect the
Registration front/rear sensor harness from the New toner sensor PCB ASSY.
Fig. 3-70
Harness routing: Refer to
.
New toner sensor flat cable
Hook
Registration front/rear sensor harness
<Front side>
New toner sensor PCB ASSY
High-voltage power
supply PCB ASSY
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...