3-37
Confidential
9.10 Document scanner unit
(1) Open the Document scanner unit.
(2) Release the Joint parts of Pull arm L and Pull arm R from each Pull arm hinge. Remove the
Pull arm L and the Pull arm R from each Pull arm guide.
(3) Remove each Pull arm spring from the Pull arm L and the Pull arm R.
Fig. 3-25
Joint part of Pull arm
Pull arm hinge
Document scanner unit
Pull arm spring
Pull arm R
Pull arm guide
Pull arm L
Pull arm spring
Pull arm guides
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...