2-97
Confidential
Ghost
Fogging
<User Check>
• Check the usage environment of the machine. Using the machine in
hot-humid or cold-dry conditions can cause this problem.
• Check whether appropriate paper type is selected on the driver.
• Select “Improve Toner Fixing” in the driver.
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
Scratch or dirt on the fuser
unit, or conductive leaf spring
deformation
Replace the fuser unit.
2
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
<User Check>
• Check the usage environment of the machine. Using the machine in
hot-humid or cold-dry conditions can cause this problem.
• Check if the acid paper is not used.
• This problem may disappear after printing multiple sheets of paper.
• Replace the toner cartridge with a new one.
• Replace the drum unit with a new one.
Step
Cause
Remedy
1
Dirt on the electrodes of the
toner cartridge and those of
the machine
Clean the electrodes of the toner cartridge.
(Refer to
.)
2
New toner sensor PCB failure
Replace the new toner sensor PCB ASSY.
3
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Note:
This problem tends to occur when the life of the drum unit or toner cartridge is expiring.
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...