2-61
Confidential
Error code 8903
The back cover sensor detected the open state when 2-sided printing is started (before the
registration of printing in the engine).
Error code 8904
The back cover sensor detected the open state during 2-sided printing (after the registration of
printing in the engine).
<User Check>
• Close the back cover correctly.
• Check that the duplex tray is set correctly.
Error code 8A01
The registration rear sensor detected that the paper fed was smaller or larger than the
specified size in duplex printing mode.
<User Check>
• Use appropriate paper (Letter to Legal).
Error code 8C00
There is no paper set in the manual feed slot on the manual feed slot printing.
<User Check>
• Set the paper in the manual feed slot.
Step
Cause
Remedy
1
Duplex tray is not set correctly
Reattach the duplex tray correctly.
2
Back cover sensor attachment failure
Reattach the back cover sensor.
3
Breakage of boss that presses
the back cover sensor
Replace the back cover.
4
Guide which pushes the back cover
sensor of the duplex tray is faulty
Replace the duplex tray.
5
Back cover sensor failure
Replace the eject sensor PCB ASSY.
6
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Registration rear actuator caught
in some sections of the machine
Reattach the registration rear actuator.
2
Registration rear sensor failure
Replace the actuator holder ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Registration front actuator caught
in some sections of the machine
Reattach the registration front actuator.
2
Connection failure of the
registration front/rear sensor
PCB harness
Reconnect the registration front/rear
sensor PCB harness.
3
Registration front sensor failure
Replace the actuator holder ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...