2-37
Confidential
Print Data Full Print Data is full.
Press Stop[x] and
delete the
previously stored
data.
The memory used to store
secure print data exceeded the
memory size for secure print
data.
Print Unable
01
Turn the power off
and then back on
again.
ASIC error or motor driver error
occurred.
Print Unable
02
Turn the power off
and then back on
again.
Cannot detect the synchronized
signal of the paper feed motor.
The speed of the paper feed
motor does not stabilize within
the specified time.
Print Unable
03
Turn the power off
and then back on
again.
Cannot detect the lock signal of
the polygon motor for the laser
unit. (second time)
Print Unable
04
Turn the power off
and then back on
again.
BD sensor failure (second time)
Print Unable
05
Turn the power off
and then back on
again.
Detected the fuser unit
temperature error.
Print Unable
09
Turn the power off
and then back on
again.
Detected irregular power supply
for more than 100 times.
Print Unable
0A
Turn the power off
and then back on
again.
Detected a fan failure.
Error message
Description
Error
codes
Refer
to:
Upper line
Lower line
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...