3-73
Confidential
9.19 Low-voltage power supply PCB ASSY
(1) Remove the two Screw cup M3x8 (black) screws, the Screw pan M4x8 screw, the Washer
spring 2-4, and the Washer 5, and remove the LVPS shield plate cover and the LVPS
insulation sheet.
Fig. 3-68
WARNING
When removing the Low-voltage power supply, DO NOT touch it
within
3 minutes
after disconnecting the AC cord as it may cause
an electric shock due to the electric charge accumulated in the
capacitor.
Assembling Note:
• Make sure to attach the LVPS insulation sheet. Failure to attach the insulation sheet
can result in fire or electrical shock.
Screw pan M4x8
Screw cup M3x8 (black)
LVPS insulation sheet
LVPS shield plate cover
Screw cup M3x8 (black)
<Back side>
Washer spring 2-4
Washer 5
Summary of Contents for DCP-2537DW