Error code 6101
The new toner sensor detected that no toner cartridge was set.
<User Check>
• Set the toner cartridge correctly.
Error code 6106
The new toner box sensor detected that no toner box was set.
<User Check>
• Set the toner box correctly.
Error code 6200
Detected that the drum unit was not set by detecting the electrodes current.
<User Check>
• Set the drum unit correctly.
Step
Cause
Remedy
1
New toner sensor PCB failure
Replace the new toner sensor PCB ASSY.
2
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
New toner box actuator coming
off or caught in some sections of
the machine
Reattach the new toner box actuator.
2
New toner box sensor failure
Replace the high-voltage power supply
PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Dirt on the electrodes of the drum
unit and those of the machine
Clean the electrodes of the drum unit and
those of the machine.
(Refer to
and
2
Dirt on the high-voltage power
supply PCB terminal
Clean the high-voltage power supply PCB
terminal.
3
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...