3-66
Confidential
2) Attach the two pieces of Double-sided tape to the Document scanner bottom cover
ASSY at the positions shown in the figure below. (If the old Double-sided tape remains
attached, replace it with a new one.)
Fig. 3-58
3) Attach the 9 mm x 9 mm Double-sided tape to the CIS carriage at the position shown in
the figure below. (If the old Double-sided tape remains attached, replace it with a new
one.)
4) Connect the First side CIS flat cable to the First side CIS unit.
5) Attach the First side CIS unit to the CIS carriage.
6) Peel the release liner of the Double-sided tape attached to the CIS carriage, and secure
the First side CIS flat cable with the tape as shown in the figure below.
Fig. 3-59
Double-sided tapes
Document scanner
bottom cover ASSY
First side CIS unit
First side CIS flat cable
CIS carriage
Double-sided tape
Summary of Contents for DCP-2537DW
Page 50: ...2 10 Confidential MP models Fig 2 6 Feed from MP tray Eject to back side Back side Front side ...
Page 51: ...2 11 Confidential 2 2 2 Scanner part Fig 2 7 Document feed path ...
Page 300: ...5 28 Confidential Print adjustment test pattern Fig 5 11 ...
Page 311: ...5 39 Confidential Print pattern Fig 5 16 W 100 K 1 K 100 Total Lattice K 5 ...
Page 316: ...5 44 Confidential Test pattern Fig 5 19 ...
Page 332: ...5 60 Confidential ...