Brooks Automation
P/N: PFD0-DI-00010, Rev 5.0.0, April 9, 2022
Service Procedures
Copyright © 2022, Brooks Automation, Inc.
113
1.
Turn off the robot power and remove the AC power cord.
2.
Remove the connector panel from the base of the robot by removing M3 X 6 flat
head screws.
3.
Remove main robot controller, PFD0-EA-00001 by removing 3 M3 X 8 SHCS and
the D-Sub standoffs from the connector side of the panel.
4.
Replace the controller and connect the wires as shown above.
5.
Replace the connector panel.
6.
Reload the robot PAC files (config directory), any project files (projects directory),
and the “Sys” files (sys directory), from a PC. These files can be copied using