PORTOFINO RESTYLING
rev.4 - 03/2008
First group
1) Press the STOP-key of the first group and then, without releasing the STOP, press (For approx.
4 seconds) the CONT. push-button (n° 1).
Entry to the programming status is shown by the simultaneous blinking of the 4 green dose LED’s
(n° 2-3-5-6) and the programming orange LED (part. n° 4
LED bicolor,pict.1
) on the key-pad of
the group being programmed.
2) Now press push-button 2 . The green LED relative to the key 2 (part.n°2 pict.1) together with the
programming orange LED (part. n° 4 pict.1) will remain alight and the brewing coffee starts.
3) Press the STOP key when the coffee has reached the required level in the cup and the dose
will be stored in memory. The green LED relative to the key 2 lights off while the others green LED
( part. 3-5-6 pict.1) and the orange programming LED begin to blink.
To program the doses relative to the keys 3,5,6, follow the instructions as per points 2,3.
4) Press STOP again to exit from the programming status.
2°-3°-4° group
At every programming, the programmed doses in the first group will be automatically transferred
on the other groups.
If you want to change the doses for the 2nd, 3rd, 4th group: please follow instructions as from point
1) to 4).
Fault signalling
The delivery of each group has a time limit which, if reached, causes the group to be blocked and the fault to be signalled by the block red LED
(part. n° 4 pict. 1).
The delivery time limit is fixed at 120 seconds.
In continuous delivery (part. n° 1pict.1), if delivery is not stopped manually using the STOP key within the time limit of 120 sec., the group will block
and the fault is signalled by the block red LED (part. n° 4 pict.1).
Should the turbine operate irregularly, the fault will be signalled by the blinking of the block red LED (part. n° 4 pict.1) on the push-button pad of
the group involved in the fault.
In this case delivery is not dosed, but if the operator does not intervene manually with the STOP key, blocking occurs when the time limit is rea
-
ched.
The water level control has been fitted with a safety device to prevent flooding.
If the water level control solenoid valve remains open for more than 90 sec., it is automatically switched off and the fault is signalled by the block
red LED (part.n° 4 pict.1) blinking on all the push-button pads.
To restart the machine, the power must be removed for at least 5 secs. and then restored.
Programming of dosed water (in seconds) - Optional, on request
To program the quantity of hot water for infusions, follow the instructions below:
1) Enter the programming status on any key pad: press STOP and then CONT without releasing STOP. The access in the programming status will
be signalized by the contemporaneous blinking of all LEDs of the key-pad.
2) Press the HOT WATER key (part.L pict.A); all green LEDs (part.2-3-5-6 pict.B) will light off and only the orange programming LED (part.4 pict.B)
will remain alight.
3) When the hot water in the cup has reached the level you want, press again the HOT WATER key (part.L pict.A) and all the green LEDs (part.2-3-5-6
pict.B) and the orange programming LED (part.4 pict.B) will blink.
4 pict.1) To memorize the quantity of hot water and to exit the programming status, press STOP.
Digital automatic version dose programming
Revision march 2008
Pict.
Pict. A
Pict. B