PORTOFINO RESTYLING
rev.4 - 03/2008
First group
1) Press the STOP-key of the first group and then, without releasing the STOP, press the
CONT. push-button (n° 1).
Entry to the programming status is shown by the simultaneous blinking of the 4 dose LED’s (n°
2-3-5-6) and the programming- LED (n° 4) on the key-pad of the group being programmed.
2) Now press the delivery push-button for the dose that is to be programmed. The LED for
the dose being programmed will remain alight and the programming- LED (n° 4) will be
blinking.
3) Press the STOP of the group when the coffee has reached the required level in the cup and
the dose will be stored in memory.
Other doses can be programmed in the same way, the only difference being the key to be
pressed.
4) Press STOP again to exit from the programming status.
2°-3°-4° group
At every programming, the programmed doses for the first group will be automatically transferred on the other groups.
If you want to change the doses for the 2nd, 3rd, 4th group: please follow as from point 1) to 4).
Fault signalling
The delivery of each group has a time limit which, if reached, causes the group to be blocked and the fault to be signalled by the block LED (n° 4).
The delivery time limit is fixed at 120 seconds.
In continuous delivery (n° 1), if delivery is not stopped manually using the STOP key within the time limit of 120 sec., the group will block and the
fault is signalled by the block LED (n° 4).
Should the turbine operate irregularly, the fault will be signalled by the blinking of the block LED (n° 4) on the push-button pad of the group involved
in the fault.
In this case delivery is not dosed, but if the operator does not intervene manually with the STOP key, blocking occurs when the time limit is rea
-
ched.
The water level control has been fitted with a safety device to prevent flooding.
If the water level control solenoid valve remains open for more than 90 sec., it is automatically switched off and the fault is signalled by the block LED
(n° 4) blinking on all the push-button pads.
To restart the machine, the power must be removed for at least 5 secs. and then restored.
Programming of dosed water (in seconds) - Optional, on request
To program the quantity of hot water for infusions, follow the instructions below:
1) Enter the programming status on any key pad: press STOP and then CONT without releasing STOP. The access in the programming status will
be signalized by the contemporaneous blinking of all LEDs of the key-pad.
2) Press the HOT WATER key (part.L fig.A); all green LEDs (part.2-3-5-6 fig.B) will light off and only the yellow programming LED (part.4 fig.B) will
remain alight.
3) When the hot water in the cup has reached the level you want, press again the HOT WATER key (part.L fig.A) and all the green LEDs (part.2-3-5-6
fig.B) and the yellow programming LED (part.4 fig.B) will blink.
4) To memorize the quantity of hot water and to exit the programming status, press STOP.
Digital automatic version dose programming
Until the 07/2002
Pict. 1
Fig. B
Fig. A