High-speed Positioning System
Configuring the System | en
47
Bosch Security Systems, Inc.
Installation Manual
F.01U.164.491 | 2.0 | 2010.03
8.3.3
Preset/Patrol/Autopan
The
Preset/Patrol/Autopan
menu sets the movement limits related to the UPH.
Feature
Description
Default Options
ENABLE PAN LIM.
Enables limits and values in degrees
taken by the device in pan.
Enables or disables complete rotation
for scan/patrol/autopan movements
(this function is useful when using
accessories with external cables, such
as infrared spotlights, where continuous
rotation of the UPH could break the
accessories themselves).
NO
YES, NO
START PAN
Enables the location that the UPH
begins to pan.
+0.00
-180.00° to
+180.00°
END PAN
Enables the location that the UPH stops
panning.
+0.00
-180.00° to
+180.00°
ENABLE TILT LIM.
Enables limits and values in degrees
taken by the device in tilt.
NO
YES, NO
START TILT
Enables the location that the UPH
begins to tilt.
+0.00
-40.00° to +90.00°
END TILT
Enables the location that the UPH stops
tilting.
+0.00
-40.00° to +90.00°
RAMP TYPE
Changes start and stop times for the
UPH. The higher the number, the
greater the acceleration/deceleration
during starting/stopping.
012
000 to 012
MOTION PARAMETERS MENU
> 1 - PRESET
>
2 - SPECIAL PRESET PARAM.
>
3 - HOME POSITION
>
4 - PATROL
>
5 - AUTOPAN
>
8 - MOTIONS RECALL
>
Feature
Description
PRESET
A pre-selected and stored combination of pan, tilt and
zoom positions that allow a set view to be recalled.
SPECIAL PRESET PARAMETER
Allows change to the default values for preset speeds and
forces it into all presets.
HOME POSITION
A special preset that is automatically recalled after an
interval of time (see other confide. menu).
PATROL
Manually change the path of the automatic cycle between
preset positions.