ID 200/C-PDP web interface 71/84
3 842 540 399/2016-11, MIT: ID 200,
Bosch Rexroth AG
8.2.4
Data logging
Output of the individual internal communication processes between the interfaces of
the device.
When the page is called up, the last 50 telegrams are output automatically. The last
50 / 100 / 200 / 512 telegrams can be requested and output via command buttons.
The last (most recent) entry is at the top.
The data log buffer contains a maximum of 512 entries and it is always the oldest
entries which are overwritten by the system.
The lines/telegrams shown have the following structure:
ttttttt.ttt src type of the cc (sts para len data…)
where:
t
= time stamp in sec.
src
= source (source of the frame)
type
= type of the frame (req=request, rsp=response)
des
= destination (destination of the frame)
with src/des =
SYS
(system)/
PDP (ProfibusDP connection)/
IO1 (serial interface/web server)
CH1 (antenna connection channel 1)
CH2 (antenna connection channel 2)
cc
= command code of the command
EN
GLISH