40/84
Communication with ID 200/C-PDP
Bosch Rexroth AG
, MIT: ID 200, 3 842 540 399/2016-11
7.3.5
Command overview
The listed commands are described in detail on the following pages.
System commands
Command code
Description of command
Fig.
eviation
4d
04h
change tag
CT
2d
02h
quit
QU
22d
16h
reset
RS
155d
9Bh
set multiplexed mode
MM
156d
9Ch
set triggermode
TM
Write/read commands
The commands
SR
(single read words),
ER
(enhanced read words) and
SW
(single write words) only work with the mobile data carrier
MDT-H
.
Not
with the
fixed code data carrier
MDT-L
!
Fixed code
Command code
Description of command
Fig.
eviation
1d
01h
single read fixcode
SF
29d
1Dh
enhanced read fixcode
EF
Read data
Command code
Description of command
Fig.
eviation
16d
10h
single read words
SR
25d
19h
enhanced read words
ER
Write data
Command code
Description of command
Fig.
eviation
64d
40h
single write words
SW
31d
1Fh
single write fixcode
SX