42/84
Communication with ID 200/C-PDP
Bosch Rexroth AG
, MIT: ID 200, 3 842 540 399/2016-11
The following data carrier types are supported:
Data carrier
type
Designation
Chip type
Access
Bits
Fixed
code
length
(bytes)
Frequency
range
High
Byte
Low
Byte
‘0’
‘2’
Unique, EM4102
(EM Microelectronic)
Fixed
code
40
5
125 kHz
‘0’
‘3’
EM4450 (EM Micro-
electronic), Titan
R/W
Fixed
code
928
32
4
125 kHz
‘1’
‘0’
Nova (Sokymat)
R/W
40
–
125 kHz
‘1’
‘1’
Q5 (Sokymat)
R/W
40
–
125 kHz
‘1’
‘4’
T5557 (Atmel)
R/W
40
–
125 kHz
‘1’
‘5’
MDT../28-L
Q5 (Sokymat)
R/W
40
–
125 kHz
‘2’
‘0’
1)
all ISO 15693-compli-
ant data carriers
R/W
Fixed
code
8
13.56 MHz
‘2’
‘1’
MDT../112-H
I-Code SLI
(NXP)
R/W
Fixed
code
896
64
8
13.56 MHz
‘2’
‘2’
Tag-it HF-I Plus
(Texas Instruments)
R/W
Fixed
code
2k
64
8
13.56 MHz
‘2’
‘3’
my-D (Infinion)
SRF55V02P
R/W
Fixed
code
1792
64
8
13.56 MHz
‘2’
‘4’
my-D (Infinion)
SRF55V10P
R/W
Fixed
code
7424
64
8
13.56 MHz
‘3’
‘3’
MDT../2K-H
Fujitsu FRAM
MB89R118
R/W
Fixed
code
16k
8
13.56 MHz
‘3’
‘5’
I-Code SLI-S
(NXP)
R/W
Fixed
code
1280
8
13.56 MHz
‘9’
‘9’
depending on
antenna
2)
–
–
–
–
–
1) This is not a data carrier type per se. It is used to read out the UID (fixed code) of all
ISO 15693-compliant data carriers.
2) The data carrier type set in the antenna as standard is selected.
In a system where only one data carrier type is used, it is advisable to set this
data carrier type. This means that the antenna can identify the data carrier faster.
Default data carrier type: In the condition as supplied, the data carrier type 99 is set
on the ID 200/C-PDP (depending on the antenna). This means that the data carrier
type is used, which is set on the antenna.
Recommendation: For operation in an automated system, set the data carrier type
used with a command.