1 690 326 006
2008-8-25
|
Robert Bosch GmbH
en
46 | FWA 43xx / 44xx | Operating System-Software
"Graph" tab
14.9.6
Signal response of the CCD servers
Fig. 10:
1 Selecting the camera.
2 Determines whether the graph is displayed or whether only the
measuring value is determined.
3 Resolution of the detail field, refer to description (9).
4 Status after reading: "Ok" or "Failed" (error).
5 The determined measuring value.
6 Progress indicator, while reading the data.
7 Position (X) and value (Y) of maximum amplitude of the
Hell(Bright) image and Differenz (Diff) image.
8 Displays the signal response of the entire CCD sensor.
9 Detail field. Displays details of the signal response in the set
resolution symmetrically for maximum amplitude.
Further executable functions via "Actions"
14.9.7
Options
Legend
Read toe pictures
The data of toe-in/out is read
for the selected camera.
Read camber picture
The data of camber
measurement is read for
the selected camera.
Further functions via Actions
Tab. 8:
"Coefficients" tab
The camera specific parameters required for correct
determination of the measuring values are displayed on
this page.
The parameters are (reflected) saved in the camera
processor and/or measuring processor and is displayed
in different display blocks (compare colour scheme in
case of "Type and version info").
Camera specific parameter
Fig. 11:
1 Coefficient for calculating track measurement value. In case
calibration sets the value "Toe x**0".
2 Coefficient for calculating camber measurement value. In case
calibration sets the value "Camber x**0".
3 Date of last calibration.
4 Displays whether the fields "Lens Corr." and "Pendulum Corr."
have a valid value.
AA = valid value for "Lens Corr."
55 = both fields include valid values.
5 Correction value for the lens inclination.
6 Correction value for the camber.
The column "Hex" displays the image of the value in the memory
of the camera processor, the column "Value" displays the
corresponding numerical values.
The functions that be called via "Actions" are
i
identical to the tab "Type and version info".
Options
Legend
Write toe zero
correction defaults
Writes a standard value for the
coefficients "Toe x**0" in the EEROM
of the selected camera processors.
Thus the problem can be solved, as
calibration is not possible because
the current value is invalid.
Write camber zero
correction defaults
Writes a standard value for
the coefficients "Camber x**0"
in the EEROM of the selected
camera processors.
Thus the problem can be solved, as
calibration is not possible because
the current value is invalid.
Further functions via Actions (Service variant)
Tab. 9:
The options function only with the service version of
i
the Sysmonitor.