1 690 326 006
2008-8-25
|
Robert Bosch GmbH
Operating System-Software | FWA 43xx / 44xx | 39
en
Adjustment program (Calibration)
14.6
Function
Track adjustment
R
Camber adjustment
R
Level adjustment
R
Follow the screen instructions for the corresponding
i
adjustment step.
When must an adjustment executed?
If there is a suspicion that the displayed measuring
R
values of the wheel alignment gauge is not correct.
If the error message "Device is out of tolerance" is
R
displayed permanently.
1
)
In case of maintenance of the wheel alignment
R
gauge.
1) As long as the wheel alignment gauge is provided with a 8 sensor
measuring system, a constant electronic separate check of the
measuring accuracy takes place automatically, which triggers the
error message "Device is out of tolerance" in case of complaints.
Save user individual data
14.7
Customer data and measuring protocol
14.7.1
The customer data and the measuring protocol is
i
saved in the following folder:
Path
C:\<program files>\FWA-CCD\WheelAligner\Aligner\
¶
General\database
Measurement report
14.7.2
The measuring protocol is saved in the folder:
i
Path
C:\<program files>\FWA-CCD\Wheel Aligner\Aligner\
¶
General\protocol
Automatically created vehicle data
14.7.3
The automatically created vehicle data is saved in
i
the folder:
Path
C:\<program files>\FWA-CCD\WheelAligner\Aligner\
¶
Targetdata\User
Breakdown of toe camera long:
Fig. 4:
Breakdown of camber camera
Fig. 5:
The breakdown of an camber camera is displayed
R
through transverse bars like in case of track camera.
The localisation of the error is basically simple
R
proportionately to the track camera, as the error are
always located in case of displayed camera.
Breakdown of
Fig. 6:
Steering axis inclination
camera