Communication processor | FWA 43xx / FWA 44xx | 11
Robert Bosch GmbH
1 690 326 006
2008-8-25
en
Communication processor
6.
Tasks
6.1
Communication control
R
Data transfer on PC (serial)
R
Saving the channel number (max. 6 transmission
R
channel)
Function
6.2
The communication processor (KP) is a central
manager for the measuring functions.
The installation location is different depending on the
type of device (radio or cable).
The connection between communication processor
R
(KP) and PC interface COM 2 is done using a 9 pin
serial cable.
The connection between communication processor
R
(KP) and 4 measuring elements (MWA) is made
using a splitter box or mess box.
Radio devices have KP built in the mess box. The
R
mess box also serves for loading the batteries.
In emergency cable operation (Breakdown radio),
i
the measuring element can be connected to the
mess box.
KP is installed in PC in case of cable equipments.
R
A splitter box manages the connection possibilities
of the measuring element.
The KP, in case of radio or cable devices, serves for
i
data transfer of measuring elements (MWA) sensors.
Pin assignment
6.3
Pin assignment
Fig. 6:
1 Power supply 12 V through PC-mains adapter
2 Serial connection COM 2 from PC
3 DIP- Switch (not used)l
4 Not assigned (for ex-works programming)
5 Not assigned
6 Outlet to splitter box
7 Not assigned
Fig. 7:
1 Serial connection COM 2 from PC
2 DIP- Switch (not used)
3 Not assigned (for ex-works programming)
4 Connection to Splitter board
.