OETIKER FAST 3000  
Safety light curtain

Supplement to the original user 
manual item no. 08903979
Issued April 2019

Item no. 08904518
OETIKER Schweiz AG

User manual

Summary of Contents for FAST 3000

Page 1: ...OETIKER FAST 3000 Safety light curtain Supplement to the original user manual item no 08903979 Issued April 2019 Item no 08904518 OETIKER Schweiz AG User manual...

Page 2: ...ncy Stop 7 6 Operation 8 6 1 Initialization 8 6 2 Verifying the closing force 9 6 3 Crimping force monitoring verification 12 6 4 Setting the force offset to zero 13 6 5 Tightening clamps 14 6 6 Frict...

Page 3: ...tion Item number OETIKER FAST 3000 CFM Ethernet IP LC 13500294 OETIKER FAST 3000 CFM PROFINET LC 13500295 Installation of the Light Curtain option does not change the purpose for which the OETIKER FAS...

Page 4: ...LC Control cabinet cpl EtherNet IP LC 13500290 Schaltschrank kpl PROFINET LC Control cabinet cpl PROFINET LC 13500289 2 hand dongle Zweihand Dongle LC Two hand dongle LC 13500297 Dongle E Stop corre s...

Page 5: ...P and 155553 for Profinet X X Connect the power supply and the signal of the 2 channel sensor to the port 350X0 using the plug supplied Power supply 24V Pin K Power supply 0 V Pin M Signal channel 1 P...

Page 6: ...2 Installing the safety light curtain Notes The safety distance of the safety light curtains must be determined by the integrator Comply with EN ISO 13855 2010 Response time of the OETIKER FAST 3000...

Page 7: ...n of the safety relay can be checked during the IO test Fig 2 Fig 2 I O test 5 1 Testing the safety light curtain X X In the GUI Graphical User Interface navigate to the graphical I O test X X Monitor...

Page 8: ...command If the safety light curtain triggers a Stop the initialization routine will be interrupted An appropriate message will appear on the GUI Acknowledge the message X X Press the Init button again...

Page 9: ...0 verifications Setting with CAL 01 SKS mode hold ME EL average see user manual OETIKER FAST 3000 1 Activate the verification Switch to the Settings tab In order to access force verification mode you...

Page 10: ...e verification unit must be correctly positioned in the bores of the crimping cut off head The locking hook must be engaged Fig 6 Positioning the locking hook OK Fig 7 Positioning the locking hook wro...

Page 11: ...Ext Force value CAL field The value that is input will be saved in the verification log 8 Press Quit routine The values are now written to the relevant log file 9 Remove verification unit 1 from the...

Page 12: ...insertion position and the tensioning unit moves to the start position The verification value is not determined and is set to the value 0 N For the sequence see also the flowchart verification of the...

Page 13: ...sage Fig 12 will appear on the GUI Acknowledge the message X X Press the OK field The notification is acknowledged the window closes Lever moves to the insertion position and the tensioning unit moves...

Page 14: ...cess is resumed at a position depending on the point at which it was interrupted This posi tion may not necessarily be the same point as the one at which the process was interrupted If at interruption...

Page 15: ...ll appear on the GUI Acknowledge the message X X Press the OK field The notification is acknowledged the window closes If the interruption occurs before the tensioning unit has reached the end positio...

Page 16: ...6 6 7 Manual movement There is no change regarding the lever The tensioning unit must be energized and initialized in order that the operator can move it manually X X Press the Power Axis The tensioni...

Page 17: ...trial communication The new list for communication must be used see separate document Status word1 Bit 21 The Status Restart Light Curtain is no longer implemented directly Technically the individual...

Page 18: ...n is inactive Decision whilst the light curtain is inactive Action for which the light curtain is active Decision whilst the light curtain is active Several scenarios are possible light curtain is act...

Page 19: ...Start clamping Release the clamp or start the tightening process Release the clamp Lever in the insertion position Tensioning unit in the start position Lever moves to the home position Lever moves t...

Page 20: ...Interruption by the light curtain Stop the tensioning unit message window active on the GUI tightening defective resumption of the process by restarting acknowledgement of the STO further in the proce...

Page 21: ...g defective resumption of the process by restarting acknowledgement of the STO further in the process Interruption by the light curtain Stop the tensioning unit message window active on the GUI tighte...

Page 22: ...hed Status of the tensioning unit active Safe torque off light curtain interrupted Status of the lever not dependent on the light curtain Interruption by the light curtain Stop the tensioning unit and...

Page 23: ...ETIKER FAST 3000 Safety light curtain Appendix Issued April 2019 23 Move the tensioning unit to the start position Move the lever to the insertion position Stopping the tensioning unit Yes Evaluate En...

Page 24: ...t curtain Stop the tensioning unit lever hide the GUI message window wait for acknowledgment reset ST move to the drives start position No Acknowledge the STO tensioning unit Start the zero offset rou...

Page 25: ...OETIKER FAST 3000 Safety light curtain Appendix Issued April 2019 25 End Tensioning unit moves to the start position Lever moves to the insertion position...

Page 26: ...tain Stop the tensioning unit lever hide the GUI message window No Acknowledging the STO tensioning unit Press the button on the GUI to start the routine Friction test value not determined value set t...

Page 27: ...oning unit moves to the friction test position Lever moves to the safe cutting position Tensioning unit moves to the ejection position the lever moves to the home position Lever moves to the insertion...

Page 28: ...Request for initialization Yes Interruption by the light curtain Stop the tensioning unit lever End No Decide on scenarios Acknowledge the notification Remove the strap Acknowledge the STO tensioning...

Page 29: ...OETIKER FAST 3000 Safety light curtain Appendix Issued April 2019 29...

Page 30: ...ice Center Further information can be found at www oetiker de Headquarters Switzerland Tel 41 44 728 55 55 info ch oetiker com China Tel 86 22 2697 1183 info cn oetiker com Germany Tel 49 76 42 6 84 0...