ACCESS KEY CONFIGURATION PARAMETERS
Up to 4096 key descriptors (8192 for the S2000-2 rev.01) can be stored in the controller database.
The keys can be Dallas iButtons, Proximity cards, PIN-codes and so on. Each key is described by a
set of parameters which is shown in Table 10.
Table 10. Key Configuration Parameters
Parameter Name
Function Description
Range
Key Type
Defines functions of the key
User
Master
Unlocking
Locking
Key Is Locked
This attribute provides temporary blocking the key
On/Off
Without
Additional Code
No additional code is necessary to identify the key while
the Two Factor Authentication mode is set for a reader
which the key is presented to (see Two Factor Authenti-
cation Section of this Manual)
On/Off
Access Group
A number of an access group which defines common
access rights and limitations which are applied to this
key and are common for all keys assigned to this access
group
0…32
Validity Limitation
Defines key activity limitations depending on date
On/Off
Validity Period
Defines the period of dates when the key is active
01.01.2000 …
… 31.12.2255
The
Key Type
parameter defines the destination of the key.
User
keys are intended to access or to arm/disarm loops.
Master
keys are intended to switch the controller into the programming mode for hardware program-
ming (adding) new keys. All keys programmed by hardware with the help of a Master key will be of
User type.
Unlocking
key is intended to open access (to implement free pass mode) and restore the Controlled
Access mode (see Access Modes Section) and also to arm/disarm alarm loops.
A
Locking
key is intended to lock access and restore the Controlled Access mode (see Access Modes
Section) and can be also used to arm/disarm loops.
The
Key is locked
switch setting prohibits operation for a key of any type. It is used to lock a key
temporary (e.g. if the key is lost) with possibility of its subsequent recovery.
The
Without Additional Code
parameter is intended to simplify identification of several keys if the
Two Factor Authentication mode is used for other keys (see Two Factor Authentication Section of this
Manual). If the Two Factor Authentication mode is not used (neither at entry, nor at exit) this key pa-
rameter is ignored.
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...