S2000-2
Operating
23
www.bolid.com
Switching to the
Controlled
mode can be implemented by:
−
repeated presenting the
Locking
key, or
−
presenting the
Unlocking
key, or
−
the relevant command of the network controller, received via the RS-485 interface
Access Locked by Arming of Access Locking Alarm Loops
If access has been locked due to the alarm loops locking access are armed, then while presenting a
combined key authorized to gain access and to disarm these loops the loops will be disarmed and the
access will be granted at the same time. For other keys (authorized to access only or having no rights
to disarm access locking loops) access will be denied.
Access locking due to alarm loops is canceled when the locking loops are disarmed.
Free Pass Mode
A reader can be switched to the
Free Pass mode
by the special
Unlocking
key or by the relevant com-
mand of a network controller received via the RS-485 interface. After that the reader LED starts flash-
ing with green color (one flash per second with short pauses), the sounders of the controller and the
reader, if enabled, playing the combination of one, two and two beeps.
In this mode a free passing is enabled to anyone without presenting any identifier.
In Free Pass mode, the controller sends opening signals to the relevant relay permanently (the relay
stays switched on or off). Thus,
this access mode is not applicable for some locking units, such
as electromagnetic strikes, for example
.
In the
Two Entrance Doors
and
Turnstile
operation modes each of the readers (access directions) can
be switched to
Free Pass
mode independently. In other operation modes (
One Entrance/Exit Door,
Swing-beam Barrier, Two Sluice Doors
) when one of the readers is switched to
Free Pass
mode, the
other reader is automatically switched to the same mode.
Switching to the
Controlled
mode can be implemented by:
−
repeated presenting the
Unlocking
key, or
−
presenting the
Locking
key, or
−
the relevant command of the network controller, received via the RS-485 interface
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...