example, compare the person who entered with an image on the PC monitor) and then make an
egress decision.
The standard time to enter the sluice after access being granted is 10 seconds.
The standard time to leave the sluice after the EXIT button being pressed is 10 seconds.
The doors must be equipped with door sensors.
Anti-passback rules can be being inspected in such the operation mode since identification is required
for passing in both directions, appropriate sluice design and the monitoring performed by a security
guard ensuring that only one person can enter when access is granted.
In order to enter the sluice, a User key with the
Access
attribute set is to be presented to a reader
mounted near the first door. If identification is completed successfully, the reader sounder generates
two beeps, the green LED is switched on, the first door is opened (unlocked) and the ACCESS
GRANTED message is generated including the code of the key presented.
If two factor authentication is applied at this reader, the reader green LED starts flashing 5 times per
second, and access is granted only after a valid additional code having been presented (see Two
Factor Authentication Section of this Manual).
After entering the sluice and closing the first door it is necessary to press the EXIT button near the
second door. This unlocks the lock of the second door to leave the sluice. The second door opening
causes the PASSAGE message to be generated. The lock is opened and the access is granted only if
the first door is closed.
From the moment of entering the sluice (first door closing) to the moment of pressing the EXIT button
of the second door no more than 20 seconds have to be expired. If within this time period the EXIT
button of the second door was not pressed, the sluice can be left only in backward direction, by press-
ing the EXIT button of the first door.
While the sluice is being passed it is regarded as occupied and no new passing in any direction is
impossible.
If EXIT buttons are located not inside the sluice but at the security post, leaving the sluice is allowed
or is not allowed by a security guard after additional control.
The procedure of passing in backward direction is similar, except for the usage of the two factor au-
thentication is configured separately for each pass direction.
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...