If identification is completed successfully, the reader sounder generates two beeps, the green LED
turns on, the door is opened (unlocked), and the ACCESS GRANTED message with the code of the
presented key specified is generated.
If the reader is programmed to implement two-factor authentication its green LED starts flashing 5
times per second and access is granted only after the valid additional code having been presented.
If two or three person access rule is applied, while identifying the key access is granted after all par-
ticipants of the access procedure having been identified.
After opening the door the reader LED enters its normal mode (is off or lit with red) and the PASSAGE
message is generated with the code of the presented key specified.
In order to open the door passing in backward direction, it is necessary to press the EXIT button that
is mounted near the door inside the premises. The reader sounder generates two beeps, the green
LED turns on, the door is opened (unlocked) and the ACCESS GRANTED message is generated
without specifying a key (impersonal). The door opening causes the impersonal PASSAGE message
to be generated. Passing through the second door is implemented similarly.
One Entrance/Exit Door Mode
In this mode the controller provides access via one access point (door) with one common locking de-
vice control circuit, with access in both passage directions being controlled via key presenting to the
readers installed both at entrance and exit.
EXIT buttons can also be used to provide access, e.g. for remote door opening from a guard post.
Standard passage time after access being granted is 10 seconds.
In such the operation mode the anti-passback rules can be applied because the identification is im-
plemented for passages in both directions. However a regular door does not protect against tailgating.
If door sensors are connected to the relevant terminals of the controller and the controller is pro-
grammed to use these ones, some extended features are available for the S2000-2 controller, among
them:
−
PASSAGE messages are generated and anti-passback rules can be applied
−
While access is granted, the relay can be activated not only for a time defined by its
Relay Acti-
vation Time
parameter (a constant), but also can be adjusted to cancel executive program just
after door opening or closing (see ‘S
witch Off After…’
parameters, Relay Configuration Parame-
ters Section of this Manual)
−
Door Held or Forced Open events are monitored for
−
While access is granted, the reader green LED lights for a time relevant to actual passage time.
If door sensors are not in use, the reader green LED lights for a time defined by the
Relay Acti-
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...