In order to pass in any direction, a User key with the
Access
attribute set is to be presented to a
reader installed before the turnstile.
If identification is completed successfully, the reader sounder generates two beeps, the green LED
lights, the turnstile is unlocked to provide one passage in specified direction, and the ACCESS
GRANTED message is generated with the code of the presented key included.
If the reader uses two factor authentications, the reader green LED starts flashing 5 times per second
and access is granted only after an additional code having been identified (see Two Factor Authenti-
cation Section of this Manual).
After opening the door the reader LED enters its normal mode (is off or lit with red) and the PASSAGE
message is generated with the code of the presented key involved.
The procedure of passing backward is similarly, except two factor authentication which is adjusted for
each reader separately.
Swing-beam Barrier Mode
In this mode the controller provides a bi-directional access via a single access point which is a swing-
beam barrier with the same bar facility for both access directions. The relay 1 is used to lift the bar
while the relay 2 is used to lower it down. To grant access in each direction requires presenting the
relevant key to one of the controller’s reader.
The standard time to pass after access being granted is 30 seconds.
In this mode anti-passback rules can be used as far as identification is required for passing (to be
more precise, for driving) in both directions.
To increase the authentication level of a system, car presence detectors are to be connected to the
alarm loop contacts of the controller. In such a case key presenting causes the controller to make
access decisions only if there is a car near the reader actually.
Passage sensors in this operation mode are used not only to detect car passing but also to prevent
swing-beam lowering down on a car located under the beam. While at least one of the sensors is ac-
tivated, the swing-beam will not be lowered.
EXIT buttons can also be used to gain access remotely, e.g. from a guard post. In the Access Locked
mode the swing-beam can be lifted only by means of the EXIT buttons. Pressing the buttons in the
Free Pass mode is ignored.
If the access is granted after the ENTRY button, the green LED of the first reader and/or green light
on the traffic control unit directed to the first reader is switched on. If the access is granted after the
EXIT button, the green LED of the second reader and/or green light on the traffic control unit directed
to the second reader is switched on.
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...