One Entrance/Exit Door Mode Programming
In order to program the S2000-2 controller for operating in One Entrance/Exit Door mode by means of
UProg Configuration Tool:
1. Select the ‘One Entrance/Exit Door’ value in Operation Mode field on the Device tab.
2. If a door sensor is in use set the first Passage Sensor flag on, else unset it.
3. If an electric strike is in use as the locking unit, set for the first relay (the Outputs tab)
−
‘Switch On for a Time’ in Executive Program field
−
1 ÷ 5s in the Relay Activation Time field (the time sufficient for the strike to be actuated)
−
‘Switch off after door being opened’ flag (for the strike to be cocked properly upon quick
passing)
Please note that Free Pass Access mode can not be implemented for an access point if the
electric strike is used as a locking unit.
If a magnet lock is in use as the locking unit, set for the first relay (the Outputs tab)
−
‘Switch Off for a Time’ in Executive Program field
−
5 ÷ 20s in the Relay Activation Time field (maximum passage time)
−
‘Switch off after door being opened’ or ‘Switch off after door being closed’ flag (for the lock
to be secured just after a passage detection)
4. If Global Anti-passback or Time&Attendance features are to be implemented within a security
system (the S2000-2 operates as a part of networked system) pay attention the access zone
numbers for both readers to be given correctly.
Other configuration parameters are adjusted depending on specific user needs and desires.
Turnstile Mode Programming
In order to program the S2000-2 controller for operating in Turnstile mode by means of UProg Con-
figuration Tool:
1. Select the ‘Turnstile’ value in Operation Mode field on the Device tab.
2. If passage sensors (a turnstile rotation detector) are in use set the relevant Passage Sensor
flags on, else unset its.
3. Set the Forced Open Monitoring and Held Open Monitoring parameters on.
4. Select the Outputs tab and set the Executive Program to ‘Switch On for a Time’ value for both
the controller relays
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...