Access will be unlocked after disarming of access locking loops.
If one or two access locking alarm loops are armed (depending on
Lock Access If…
parameters set-
ting), presenting a combined key (without entering the Ready to Arm/Disarm mode) will cause disarm-
ing the loop (loops) and access granting (of cause, if the key is authorized to disarm the access lock-
ing alarm loops). Therefore, in general, the Ready to Arm/Disarm mode has to be activated by press-
ing the Arming Request button only for arming the loops by means of combined keys, disarming being
implemented automatically upon first access granting based on a combined key.
It is possible to arm/disarm alarm loops by means of combined cards (designed for arming/disarming
and access) without switching the controller to the Ready to Arm/Disarm mode. For this purpose a
non-zero value of the
Time to Hold Keys for arming/disarming
reader parameter has to be set. If the
combined card is presented to a reader and keep it presented for the set time, the corresponding
alarm loops will be armed/disarmed. If the card is presented for the short time, access will be granted
(actual relay actuation and generation of access granted event will take place with insignificant delay,
when the card is taken away from the reader). This way of arming/disarming can be used only for a
reader with Touch Memory output interface. If the Time to Hold Keys for Arming/Disarming parameter
is set to zero, this way of arming/disarming is disabled and the controller will grand access instanta-
neously.
Not only the User keys, but also Locking and Unlocking keys can be combined (designed for
arming/disarming). All that is needed
to assign the keys with an access group which is designed to
enable alarm loop arming/disarming. To control arming/disarming of the alarm loops by means of
such combined keys the controller also has to be switched to Ready to Arm/Disarm mode or the key
has to be held near the reader within Time to Hold Keys for Arming/Disarming.
Arming/disarming commands are delivered to the controller via the RS-485 interface the S2000-2 is
controlled from a PC, from a S2000/S20000M control console or from one of Orion system devices by
using partition arming/disarming mechanism. In particular, this S2000-2 controller can be used to con-
trol security and fire alarms in a system.
Transmitting a security system such events as intruder alarms, loop arming, loop disarming or loop
arming fault is realized by sending them via the RS-485 interface to a network controller. Alarm mes-
sages dealt with alarm loops can be indicated by means of LEDs and sounders of the controller and
its readers.
In order to activate sound indication of loop alarms, the relevant category of sound signals has to be
activated for the controller or the reader respectively (see System Configuration Parameters and
Reader Configuration Parameters Sections of this Manual).
In order to activate visual indication of loop alarms by means of the controller or reader LEDs, the
Indicate Loop Alarms
attributes have to be properly set for the reader (see Reader Configuration Pa-
rameters Section of this Manual).
Summary of Contents for S2000-2
Page 1: ...Orion ISS Access Controller S2000 2 User s Manual ISO 9001 ...
Page 5: ...S2000 2 Features and Design 5 www bolid com FEATURES AND DESIGN ...
Page 8: ...Orion ISS www bolid com 8 ...
Page 9: ...S2000 2 Specifications 9 www bolid com SPECIFICATIONS ...
Page 12: ...Orion ISS www bolid com 12 ...
Page 13: ...S2000 2 Operating 13 www bolid com OPERATING ...
Page 47: ...S2000 2 Installation 47 www bolid com INSTALLATION ...
Page 67: ...S2000 2 S2000 2 Programming 67 www bolid com S2000 2 PROGRAMMING ...
Page 89: ...S2000 2 Maintenance 89 www bolid com MAINTENANCE ...
Page 94: ...Orion ISS www bolid com 94 ...
Page 95: ...S2000 2 95 www bolid com Appendix Connecting Some Models of Readers to the S2000 2 Controller ...