28-6-2011 31 033000=13069F
If then a timed event is taking place, where COMFORT2 of thermostat 2 is set to 22°C, and
ambient temperature measured by thermostat is still 20°C, the console will send an ON
message to the respective HA address. (see chapter 7.8 for timed temperature ° events).
Temperature levels and settings in a glance:
LEVEL
SET
USED BY
Ambient temperature
Measured by individual thermostat always
Thermostat Comfort level
Set individually per thermostat
normal mode
Console Comfort level
Set in console, per thermostat T1–T4 timed events only
Console Economy level
Set in console, applies for all
armed/timed/phone
Thermostats
Console Frost level
Set in console, applies for all
armed/timed/phone
Thermostats
The Console Comfort levels can only be used with timer events.
To set the different temperature levels inside the console:
1. To access the menu, press the menu UP or menu DOWN button. The display now shows
ENTER PIN.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The
display is cleared and shows a * for each number entered.
3. When the PIN code has been entered correctly, the word
INSTALL
will show up on the
display.
4. Use the menu buttons UP/DOWN to go to menu item
7. OPTIONS
. Press OK to select this
menu item. You can also go to this menu item directly by pressing a 7 on the number pad.
5. Use the menu buttons UP/DOWN to go to menu item
SET COMFORT.
Press OK to select
this menu item.
6. Use the menu buttons UP/DOWN to select the desired temperature setting,
COMFORT1, COMFORT2 … COMFORT4
, for respective thermostats 1-4, and
ECONOMY
and
FROST
in general; press OK.
7. Use the number pad to set the corresponding absolute temperature. Press OK.
8. Press CLEAR again to quit the menu.
The TS10 Thermostat heat- and cool function as well as operating instructions are described
in the manual of the DigiMax210 thermostat.
The setbacks can be used when in ARM AWAY mode, by Arming the system on the console
direct, or remotely by phone. Response to button presses of the ARM AWAY button:
Once: remains Comfort settings as set to the individual thermostats T1 – T4.
Twice: set all thermostat levels to Economy level as set to console.
Third press: set all thermostat levels to Frost level as set to the console.
11. Telephone functions
11.1 Calling the security system
The SC28 alarm system is equipped with a call-in function. This means that you can dial in
to the console remotely via any telephone or mobile phone. You can also control your
lights, devices and temperature setbacks via your phone. The system has a built-in speech
chip that guides you through the menus.
11.2 Activating the call-in function
The call-in function is switched off in the factory settings. You can switch the function on via
the menu
OPTIONS/ANSWER TYPE.
You can choose one of the following three options: