Chapter 4 Configuration
MT1000A
Installation and Operation Manual
4-10
Working with the System Log File
MT1000A
Channel Port Status
Status (No alarm)
Line code (B8ZS)
Balance mode (Balance)
1. Channel Num > (1)
>
Please select item <1 to 1>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-12. Channel Port Status Screen
4.5
Working with the System Log File
Displaying the System Log File
To display the system log file:
•
From the System Monitoring menu (
Figure 4-5
), choose
System Log File
.
The System Log File screen (
Figure 4-13
) is displayed.
MT1000A
System Log File
Source Alarm Status Time
1 Local Main Link Line AIS occurred Major 2:1:13
| 2 Local Device No connection to remote Off 5:17:11
| 3 Local CH1 LOS Minor 5:19:13
v 4 Local Device Power supply A failure Major 9:1:14
5 Local Device Redundancy is not available Major 13:34:14
6 Remote Device Power supply B failure Major 15:41:12
7 Remote Device Power supply B failure Off 16:22:14
8 Remote CH2 LOS Minor 22:3:14
9 Event Buffer Overflow Event 23:41:14
>
Please select item <1 to 13
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure 4-13. System Log File Screen