Chapter 2 Installation and Setup
MT1000A
Installation and Operation Manual
2-6 Interfaces
and
Connections
Closing the MT1000A Cover
After completing the internal settings, replace the cover on the unit.
To close the cover:
1. Place the top cover on the unit.
2. Insert the screw on both side panels.
3. Insert the eight screws on the top panel
Insert the original cover screws in their positions and tighten carefully. Do not use
excessive force.
2.6
Interfaces and Connections
Connector Location
Figure 2-2
shows a typical MT1000A rear panel, and identifies connector locations.
Connector pin allocations appear in Appendix A.
TX
RX
TX
RX
Optional Backup
Power Supply
Fiber Optic Links
T1 Tributary Channels
Alarm Connector
Power
Connector
Figure 2-2 Typical MT1000A Rear Panel
Connecting the Tributary Channels
Each tributary interface includes one RJ-45 connector.
To connect the tributary channels:
•
Connect each of the tributary cables to the connector(s) corresponding to the
interface in use. Connect to the RJ-45 connectors designated CH1, CH2, CH3
and CH4.
Connecting the Fiber Optic Links
Each fiber optic interface is terminated in two ST, FC or FC/PC connectors, in
accordance with the ordered option. The connection to the fiber optic link (A and
B) is made using one of two groups of connectors – one for link A and the other for
the optional link B. The connector types (ST, SC, FC/PC) depend on the interface
option in use.