Press the
AUTO/OFF
button on the OxiBOSS until
it reads “
Pump is now in AUTO mode
”.
If the calibration failure persists, the ORP probe will
most likely need to be replaced. This can be
purchased online at bionizer.com.au.
!
Disconnect the ORP Probe from the OxiBOSS (to
prevent twisting the cable) and re-fit into the Tee.
Re-connect the ORP Probe to OxiBOSS when
done.
!
Switch your pool equipment back on.
!
Re-connect the pool pump to the Bionizer power
outlet, or the power output to which it was
connected before starting this procedure.
Calibration Failure
Clean the ORP probe as per the troubleshooting
section on page 17, then retry calibration.
!
If using a Bionizer, ensure that it is set to “Auto”
mode.
If ORP calibration fails, the OxiBOSS will display this
message:
6. Re-fit ORP Probe and Power Connections
MAINTENANCE
14