TROUBLESHOOTING
OxiBOSS ALERTS AND GENERAL MESSAGES.
Alert Messages
Reminder Messages
General Messages
Hardware Failure Messages
Possible Causes and Remedies
Action Required
Explanation of Message
Explanation of Message
!
The OxiBOSS will not attempt any further sanitiser addition until the alarm is
cleared. Press
AUTO / OFF
to clear the alarm after rectifying the issue.
!
Please refer to page 12 for a complete list of possible causes and remedies
when the Alarm message is flashing.
ORP reading has been below Set Point for more than 4 hours of operation.
!
Calibrate the ORP Probe as per page 1.
!
This reminder is displayed 6 months after the last ORP Calibration.
!
Lubricate or change the Squeeze Tube as per page 15.
!
This reminder is displayed when the peristaltic dosing pump has exceeded
50 hours of operation since the last time the Squeeze Tube was lubricated or
changed.
!
This message is displayed each time the OxiBOSS is switched on.
!
If you need to contact Bionizer for technical support, we may ask you the
software version number (“v2.1” in this example).
!
On this screen, the OxiBOSS displays the accumulated pump Squeeze Tube
time, and the number of days since the last ORP probe calibration.
!
This message is displayed each time the OxiBOSS is switched on, after the
version screen above.
!
The OxiBOSS has not been able to obtain data from the internal clock chip.
!
Switch the OxiBOSS off for 5 seconds, then back on again. If the problem
persists, return the OxiBOSS to Bionizer for repair.
!
Switch the OxiBOSS off for 5 seconds, then back on again. If the problem
persists, return the OxiBOSS to Bionizer for repair.
!
This message can be error number 1 to 9.
18