background image

OxiBOSS INSTALLATION

2.  Drill a 7.0mm or 1/4 inch hole into the top of the 

drum lid.

3.  Push the end of the drum weight hose through 

the drum lid.

1.  Remove the lid from the chemical drum that you 

will use. 

DRUM WEIGHT HOSE INSTALLATION

4.  Fit the hose onto the drum weight tube fitting in 

the same way as described in the 

Tee Piece Hose 

Installation 

section above and illustration below.

1.  Fit Teflon tape onto the thread of the  ORP Probe. Carefully remove the 

protective cap from the tip of the probe.

ORP PROBE INSTALLATION

2.  Screw the ORP Probe into the Tee piece thread. Tighten firmly by hand. A 

tool may be used for another ½ to 1 turn, if the fitting is leaking when the 
pump is running. DO NOT OVER-TIGHTEN.

3.  After the ORP Probe is installed in the Tee piece, connect plug on the ORP 

Probe cable into the probe socket on the OxiBOSS. Push the plug into place 
and  1/4  turn  clockwise  to  lock  it  into  place.  See  the  OxiProbe  socket 
diagram, Page 4.

AFTER ALL HOSE FITTINGS ARE COMPLETED, AND THE PROBE IS FITTED, TEST 
THE  SYSTEM  WITH  FRESH  WATER,  USING  THE  MANUAL  DOSE  FUNCTION 
(PAGE 12). CHECK CAREFULLY FOR ANY LEAKS AND CORRECT AS NEEDED.

1.  Remove the nut from the one way valve fitting on 

the Tee piece. 

2.  Slip the Nut over the hose.

TEE PIECE HOSE INSTALLATION

3.  Push the hose firmly onto the tube fitting.

4.  Tighten  the  nut  over  the  hose.  Tighten  firmly 

with fingers. DO NOT USE A TOOL.

10

Summary of Contents for OxiBOSS

Page 1: ...d before you call us for advice Version 2 1a 19 Sep 2019 bionizer com au bionizer com Bionizer highly recommends that a pH BOSS automatic pH Controller is used together with the OxiBOSS Controller Whe...

Page 2: ...NG 17 BIONIZER CONTACT INFORMATION 20 CONTROL BOX INSTALLATION 9 MAINTENANCE 13 PUMP SQUEEZE TUBE LUBRICATION AND REPLACEMENT 15 TEE PIECE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 10 AUTO OFF BUTTON...

Page 3: ...her load would need around 4ppM of Chlorine to maintain a chemical activity of 650 mV ORP A pool that is not being used during winter with low water temperature may need 1ppM of Chlorine to maintain t...

Page 4: ...omaticsanitisercontrol Presstoscrollthroughthesixusersettingmenus Presstosavechangeswhenadjustingsettings 16x2Linealphanumeric LCD with LED backlight Presstomakeschangestousersettings Precision high q...

Page 5: ...Main OxiBOSS Display 5 ThecurrentORPofthePool The Set Point at which the OxiBOSS will maintaintheORPlevel Seepage12 The arrow is also animated whenever thedosingpumpisaddingchemical The Arrow here ind...

Page 6: ...nd using this electrical equipment includingthefollowing 5 Always power the OxiBOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the OxiBOSS and will void your warranty 5 Re...

Page 7: ...section of pipe sufficient for the Probe Injection Tee piece For 40mm 1 5 pipe where the reducing busheswillbeused cutouta7cm 2 75 section ofpipe NOTE Turn off all valves prior to fitting the T piece...

Page 8: ...rom vertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE ORP PROBE HORIZONTAL WHICH WILL RENDER THE ORP PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount...

Page 9: ...resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty 1 Choose a position that will allow you to see the OxiBOSS Display easily Fix the control box in positionusi...

Page 10: ...y by hand A tool may be used for another to 1 turn if the fitting is leaking when the pumpisrunning DO NOT OVER TIGHTEN 3 After the ORP Probe is installed in the Tee piece connect plug on the ORP Prob...

Page 11: ...water This is related tobothpoolsize andpump pipesetup In general a smaller pool would use a lower Dose Setting than a large pool However other factors can affectthis suchaspoolturnovertime 20 250 000...

Page 12: ...THE SANITISER PUMP WILL BE DISABLED AND THE OxiBOSS WILL NOT PUMP MORE SANITISER UNTIL THE ALARM HAS BEEN RESET Problem DoseSettingistoolowortoohigh Fix See page 11 for information on how to changethe...

Page 13: ...rnalpowersource pleaseensurethat the pool pump is switched off and unplugged duringtheentirecalibrationprocedure The ORP Probe should be calibrated to ensure that the readout is correct Calibration is...

Page 14: ...t into the Tee Re connect the ORP Probe to OxiBOSS when done Switchyourpoolequipmentbackon Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestar...

Page 15: ...an be pushedbackinplace Pull off the pump cover Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside MAINTENANCE Apply Silicon grease here Pull out the pump rotor a littl...

Page 16: ...her lubricated or replaced the last step is to reset the Squeeze Tube remindertozero Replacement Squeeze Tubes are supplied with new Supply and Delivery tubes pre fitted for your convenience It will b...

Page 17: ...ntactyourdistributororBionizer Faulty AC DC poweradaptor FaultyOxiBOSS mainunit ReturntoBionizerforrepair ReducetheDoseSettingbyonelevelandcheckin2days DoseSettingissettoohigh Replacesqueezetubeand or...

Page 18: ...ayed when the peristaltic dosing pump has exceeded 50 hours of operation since the last time the Squeeze Tube was lubricated or changed ThismessageisdisplayedeachtimetheOxiBOSSisswitchedon If you need...

Page 19: ...s Reduces Copper Ion loss from various environmental stressors Use a double dose of Ionlife when going away for extended holidays to help ensure that you return to a pristinepool MayextendthelifeofCop...

Page 20: ...Email relax bionizer com 16427 N Scottsdale Rd Suite 410 USA Toll Free 1 855 8 IONIZE Web bionizer com QLD 4558 Australia Web bionizer com au 1 173 Bradman Ave Phone 1800 10 62 74 Fax 61 7 5443 6700 E...