PROGRAMMING YOUR OxiBOSS
12
!
Press
PROGRAM / SET
to start pumping.
!
Use the
p
and
q
buttons to enter 1 to 25 Litres.
Please note that the OxiBOSS factory preset default
Set Point is 650mV. This can be adjusted up or down,
based on pool balance tests.
!
Press
PROGRAM / SET
to save.
!
Take care when using this function, to not
overdose the pool with sanitiser.
T h e ra n ge o f t h i s
setting is from 0 to 25
Litres.
Use this function to add a measured dose of sanitiser.
CHANGING THE ORP SET POINT
!
Use the Use the
p
and
q
buttons to enter a new
Set Point value.
MANUAL DOSE
Alternatively, press
AUTO / OFF
to quit without
saving changes.
Problem
...ORP Probe is broken or faulty.
Fix
.............Check all tube and hose fittings for
leakage. Re-fit or replace as necessary.
!
Press
PROGRAM / SET
to save.
When the alarm has been triggered, the OxiBOSS
will sound the beeper and also display will
alternative between an alarm screen and “
” in
Alrm
the status message :
!
Use the Use the
p
and
q
buttons to select On or
Off.
Use
PROGRAM / SET
to select Alarm.
You must press AUTO / OFF to reset the alarm and
return to normal operation.
THE SANITISER PUMP WILL BE DISABLED AND
THE OxiBOSS WILL NOT PUMP MORE SANITISER
UNTIL THE ALARM HAS BEEN RESET.
Problem
...Dose Setting is too low or too high.
Fix
.............See page 11 for information on how to
change the Dose Setting.
ALARM FUNCTION
When the Alarm is set to ON, the OxiBOSS will sound
the beeper and disable the sanitiser pump when the
ORP is below the set point for more than 4 hours.
The reason for the alarm being triggered should be
found and rectified too. It could be due to any of the
following :
Problem
...ORP Reading is incorrect
!
Press
AUTO / OFF
to quit without saving changes.
Fix
.............Refill the sanitiser drum.
Fix
.............Re-calibrate the ORP Probe. See page 13.
Fix
.............If re-calibration is not possible, then
replace the ORP Probe.
When the Alarm is set to OFF, the alarm will never be
triggered, regardless of the ORP reading. Only
advanced users should set the alarm to OFF, and only
temporarily while the cause of the alarm beeping is
being rectified.
A replacement ORP Probe can be
ordered by telephone or online at
www.bionizer.com.au
Problem
...Sanitiser drum is empty.
Problem
...Pump is not pumping sanitiser correctly.
Check squeeze tube inside pump for
leakage and replace if necessary. See
page 15.
A replacement Squeeze Tube can be
ordered by telephone or online at
www.bionizer.com.au