PROGRAMMING YOUR OxiBOSS

12

!

Press 

PROGRAM / SET

 to start pumping. 

!

Use the 

p

 and 

q

 buttons to enter 1 to 25 Litres.

Please note that the OxiBOSS factory preset default 
Set Point is 650mV. This can be adjusted up or down, 
based on pool balance tests.

!

Press 

PROGRAM / SET

 to save. 

!

Take  care  when  using  this  function,  to  not 
overdose the pool with sanitiser.

T h e   ra n ge   o f   t h i s 
setting is from 0 to 25 
Litres.

Use this function to add a measured dose of sanitiser. 

CHANGING THE ORP SET POINT

!

Use the Use the 

p

 and 

q

 buttons to enter a new 

Set Point value.

MANUAL DOSE

Alternatively, press 

AUTO /  OFF

 to quit without 

saving changes.

Problem

...ORP Probe is broken or faulty. 

Fix

.............Check  all  tube  and  hose  fittings  for 

leakage. Re-fit or replace as necessary.

!

Press 

PROGRAM / SET

 to save. 

When  the  alarm  has  been  triggered,  the  OxiBOSS 
will  sound  the  beeper  and  also  display  will 
alternative between an alarm screen and “

” in 

Alrm

the status  message :

!

Use the Use the 

p

 and 

q

 

buttons to select On or 

Off.

Use 

PROGRAM / SET

 to select Alarm.

You must press AUTO / OFF to reset the alarm and 
return to normal operation.

THE  SANITISER  PUMP  WILL  BE  DISABLED  AND 
THE OxiBOSS WILL NOT PUMP MORE SANITISER 
UNTIL THE ALARM HAS BEEN RESET.

Problem

...Dose Setting is too low or too high.

Fix

.............See  page  11  for  information  on  how  to 

change the Dose Setting.

ALARM FUNCTION

When the Alarm is set to ON, the OxiBOSS will sound 
the beeper and disable the sanitiser pump when the 
ORP is below the set point for more than 4 hours.

The reason for the alarm being triggered should be 
found and rectified too. It could be due to any of the 
following :

Problem

...ORP Reading is incorrect

!

Press 

AUTO / OFF

 to quit without saving changes.

Fix

.............Refill the sanitiser drum.

Fix

.............Re-calibrate the ORP Probe. See page 13.

Fix

.............If  re-calibration  is  not  possible,  then 

replace the ORP Probe.

When the Alarm is set to OFF, the alarm will never be 
triggered,  regardless  of  the  ORP  reading.  Only 
advanced users should set the alarm to OFF, and only 
temporarily while the cause of the alarm beeping is 
being rectified.

A replacement ORP Probe can be 
ordered by telephone or online at 
www.bionizer.com.au

Problem

...Sanitiser drum is empty.

Problem

...Pump is not pumping sanitiser correctly. 

Check  squeeze  tube  inside  pump  for 
leakage  and  replace  if  necessary.  See 
page 15.
A replacement Squeeze Tube can be 
ordered by telephone or online at  
www.bionizer.com.au

Summary of Contents for OxiBOSS

Page 1: ...d before you call us for advice Version 2 1a 19 Sep 2019 bionizer com au bionizer com Bionizer highly recommends that a pH BOSS automatic pH Controller is used together with the OxiBOSS Controller Whe...

Page 2: ...NG 17 BIONIZER CONTACT INFORMATION 20 CONTROL BOX INSTALLATION 9 MAINTENANCE 13 PUMP SQUEEZE TUBE LUBRICATION AND REPLACEMENT 15 TEE PIECE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 10 AUTO OFF BUTTON...

Page 3: ...her load would need around 4ppM of Chlorine to maintain a chemical activity of 650 mV ORP A pool that is not being used during winter with low water temperature may need 1ppM of Chlorine to maintain t...

Page 4: ...omaticsanitisercontrol Presstoscrollthroughthesixusersettingmenus Presstosavechangeswhenadjustingsettings 16x2Linealphanumeric LCD with LED backlight Presstomakeschangestousersettings Precision high q...

Page 5: ...Main OxiBOSS Display 5 ThecurrentORPofthePool The Set Point at which the OxiBOSS will maintaintheORPlevel Seepage12 The arrow is also animated whenever thedosingpumpisaddingchemical The Arrow here ind...

Page 6: ...nd using this electrical equipment includingthefollowing 5 Always power the OxiBOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the OxiBOSS and will void your warranty 5 Re...

Page 7: ...section of pipe sufficient for the Probe Injection Tee piece For 40mm 1 5 pipe where the reducing busheswillbeused cutouta7cm 2 75 section ofpipe NOTE Turn off all valves prior to fitting the T piece...

Page 8: ...rom vertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE ORP PROBE HORIZONTAL WHICH WILL RENDER THE ORP PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount...

Page 9: ...resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty 1 Choose a position that will allow you to see the OxiBOSS Display easily Fix the control box in positionusi...

Page 10: ...y by hand A tool may be used for another to 1 turn if the fitting is leaking when the pumpisrunning DO NOT OVER TIGHTEN 3 After the ORP Probe is installed in the Tee piece connect plug on the ORP Prob...

Page 11: ...water This is related tobothpoolsize andpump pipesetup In general a smaller pool would use a lower Dose Setting than a large pool However other factors can affectthis suchaspoolturnovertime 20 250 000...

Page 12: ...THE SANITISER PUMP WILL BE DISABLED AND THE OxiBOSS WILL NOT PUMP MORE SANITISER UNTIL THE ALARM HAS BEEN RESET Problem DoseSettingistoolowortoohigh Fix See page 11 for information on how to changethe...

Page 13: ...rnalpowersource pleaseensurethat the pool pump is switched off and unplugged duringtheentirecalibrationprocedure The ORP Probe should be calibrated to ensure that the readout is correct Calibration is...

Page 14: ...t into the Tee Re connect the ORP Probe to OxiBOSS when done Switchyourpoolequipmentbackon Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestar...

Page 15: ...an be pushedbackinplace Pull off the pump cover Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside MAINTENANCE Apply Silicon grease here Pull out the pump rotor a littl...

Page 16: ...her lubricated or replaced the last step is to reset the Squeeze Tube remindertozero Replacement Squeeze Tubes are supplied with new Supply and Delivery tubes pre fitted for your convenience It will b...

Page 17: ...ntactyourdistributororBionizer Faulty AC DC poweradaptor FaultyOxiBOSS mainunit ReturntoBionizerforrepair ReducetheDoseSettingbyonelevelandcheckin2days DoseSettingissettoohigh Replacesqueezetubeand or...

Page 18: ...ayed when the peristaltic dosing pump has exceeded 50 hours of operation since the last time the Squeeze Tube was lubricated or changed ThismessageisdisplayedeachtimetheOxiBOSSisswitchedon If you need...

Page 19: ...s Reduces Copper Ion loss from various environmental stressors Use a double dose of Ionlife when going away for extended holidays to help ensure that you return to a pristinepool MayextendthelifeofCop...

Page 20: ...Email relax bionizer com 16427 N Scottsdale Rd Suite 410 USA Toll Free 1 855 8 IONIZE Web bionizer com QLD 4558 Australia Web bionizer com au 1 173 Bradman Ave Phone 1800 10 62 74 Fax 61 7 5443 6700 E...

Reviews: