NOTE THAT THE 10cm SPACINGS SHOWN ABOVE ARE FROM THE EDGES OF THE PODS, NOT 
THE CENTRE OF THE PODS.

OxiBOSS INSTALLATION

READ THE DO’S AND DON’TS AND TAKE THE TIME TO INSTALL CORRECTLY.

OxiBOSS INSTALLATION

3. 

Be  sure  to  install  the  Tee  piece  in  the  correct 
direction of the water flow, as per the arrow on 
the Tee.

 

The  Tee  piece  should  be  installed  so  that  the 

O

ORP  Probe  is  within  30   of  vertical.  (See  next 
page)

1.  Installing  your  OxiBOSS  takes  around  30 

minutes.

4.  The  Probe/Injection  Tee  must  be  fitted  on  the 

pipe that sends water back to the pool after it has 
been filtered (the “Return Line”).

The OxiBOSS can be installed onto a new pool or an 
existing pool with minimal pool preparation. Ensure 
that the pool is correctly balanced, in particular the 
pH.

TEE PIECE INSTALLATION

3.  If installing it yourself you will need :

1.  For 50mm (2") pipe, cut out a 6cm (2.5") section 

of  pipe  sufficient  for  the  Probe/Injection  Tee 
piece. For 40mm (1.5") pipe, where the reducing 
bushes will be used, cut out a 7cm (2.75") section 
of pipe. 

NOTE:

 Turn off all valves prior to fitting the T-piece 

(avoid  leaks),  and  turn  them  back  on  again  before 
switching pool pump back on.

!

PVC pressure glue and primer.

!

A fine tooth saw.

2.  Alternatively engage a competent person to do 

the job.

!

If a pH BOSS, Eco-Oxidizer and/or Bionizer is 

installed, fit the OxiBOSS Tee LAST, AFTER the 
pH Tee, Eco-Oxidizer Pod and Bionizer Pod .

!

If a Salt Chlorinator is installed, fit the OxiBOSS 

tee AFTER the Salt Chlorinator cell.

2.  If the Tee piece diameter is larger than the pipe 

then use the 50mm to 40mm reducing bushes 
provided  by  glueing  them  in  place  in  the  Tee 
piece  before  fitting.  The  pipe  should  now  fit 
snugly into the Tee piece.

Filter

For sand filters,

glass or silica sand

media provides

optimum results.

Filter

Pressure

Pool

Pump

pH Tee

ORP Tee

10cm

min

10cm

min

Oxidizing

Pod

Ionizing

Pod

If a heater is 

installed, then fit 

the heater FIRST.

FLOW  DIRECTION

FLOW  DIRECTION

7

10cm

min

Summary of Contents for OxiBOSS

Page 1: ...d before you call us for advice Version 2 1a 19 Sep 2019 bionizer com au bionizer com Bionizer highly recommends that a pH BOSS automatic pH Controller is used together with the OxiBOSS Controller Whe...

Page 2: ...NG 17 BIONIZER CONTACT INFORMATION 20 CONTROL BOX INSTALLATION 9 MAINTENANCE 13 PUMP SQUEEZE TUBE LUBRICATION AND REPLACEMENT 15 TEE PIECE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 10 AUTO OFF BUTTON...

Page 3: ...her load would need around 4ppM of Chlorine to maintain a chemical activity of 650 mV ORP A pool that is not being used during winter with low water temperature may need 1ppM of Chlorine to maintain t...

Page 4: ...omaticsanitisercontrol Presstoscrollthroughthesixusersettingmenus Presstosavechangeswhenadjustingsettings 16x2Linealphanumeric LCD with LED backlight Presstomakeschangestousersettings Precision high q...

Page 5: ...Main OxiBOSS Display 5 ThecurrentORPofthePool The Set Point at which the OxiBOSS will maintaintheORPlevel Seepage12 The arrow is also animated whenever thedosingpumpisaddingchemical The Arrow here ind...

Page 6: ...nd using this electrical equipment includingthefollowing 5 Always power the OxiBOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the OxiBOSS and will void your warranty 5 Re...

Page 7: ...section of pipe sufficient for the Probe Injection Tee piece For 40mm 1 5 pipe where the reducing busheswillbeused cutouta7cm 2 75 section ofpipe NOTE Turn off all valves prior to fitting the T piece...

Page 8: ...rom vertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE ORP PROBE HORIZONTAL WHICH WILL RENDER THE ORP PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount...

Page 9: ...resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty 1 Choose a position that will allow you to see the OxiBOSS Display easily Fix the control box in positionusi...

Page 10: ...y by hand A tool may be used for another to 1 turn if the fitting is leaking when the pumpisrunning DO NOT OVER TIGHTEN 3 After the ORP Probe is installed in the Tee piece connect plug on the ORP Prob...

Page 11: ...water This is related tobothpoolsize andpump pipesetup In general a smaller pool would use a lower Dose Setting than a large pool However other factors can affectthis suchaspoolturnovertime 20 250 000...

Page 12: ...THE SANITISER PUMP WILL BE DISABLED AND THE OxiBOSS WILL NOT PUMP MORE SANITISER UNTIL THE ALARM HAS BEEN RESET Problem DoseSettingistoolowortoohigh Fix See page 11 for information on how to changethe...

Page 13: ...rnalpowersource pleaseensurethat the pool pump is switched off and unplugged duringtheentirecalibrationprocedure The ORP Probe should be calibrated to ensure that the readout is correct Calibration is...

Page 14: ...t into the Tee Re connect the ORP Probe to OxiBOSS when done Switchyourpoolequipmentbackon Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestar...

Page 15: ...an be pushedbackinplace Pull off the pump cover Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside MAINTENANCE Apply Silicon grease here Pull out the pump rotor a littl...

Page 16: ...her lubricated or replaced the last step is to reset the Squeeze Tube remindertozero Replacement Squeeze Tubes are supplied with new Supply and Delivery tubes pre fitted for your convenience It will b...

Page 17: ...ntactyourdistributororBionizer Faulty AC DC poweradaptor FaultyOxiBOSS mainunit ReturntoBionizerforrepair ReducetheDoseSettingbyonelevelandcheckin2days DoseSettingissettoohigh Replacesqueezetubeand or...

Page 18: ...ayed when the peristaltic dosing pump has exceeded 50 hours of operation since the last time the Squeeze Tube was lubricated or changed ThismessageisdisplayedeachtimetheOxiBOSSisswitchedon If you need...

Page 19: ...s Reduces Copper Ion loss from various environmental stressors Use a double dose of Ionlife when going away for extended holidays to help ensure that you return to a pristinepool MayextendthelifeofCop...

Page 20: ...Email relax bionizer com 16427 N Scottsdale Rd Suite 410 USA Toll Free 1 855 8 IONIZE Web bionizer com QLD 4558 Australia Web bionizer com au 1 173 Bradman Ave Phone 1800 10 62 74 Fax 61 7 5443 6700 E...

Reviews: