OxiBOSS INSTALLATION

SET  THE  TIMER  FOR  THIS  OUTLET  TO  THE 
SAME SETTING AS THE POOL PUMP OUTLET.

2.  Make sure that the unit is undercover and that the 

Display is not in direct sunlight as it is not covered 
by warranty if it is damaged by sunlight.

2)  Plug  the  optional  AC/DC  power  adaptor  into 
one of the two mains power outlets provided on 
the Bionizer unit.

4.  Connect the low voltage plug to the OxiBOSS DC 

Power  Socket  (see  Page  4).  Use  only  a  genuine 
Bionizer power adaptor or warranty may be void.

1)  Connect the short DC to DC adaptor lead from 

one  of  the  Bionizer  DC  outlet  sockets  to  the 
OxiBOSS DC Power Socket.

3)  When  connecting  to  a  pool  control  system, 
connect the  AC/DC adaptor to a suitable power 
outlet on the control system, if available.

CONTROL BOX INSTALLATION

The control box MUST be mounted vertically, with 
the  cables  at  the  bottom,  in  order  to  be  weather 
resistant. Any water ingress due to the unit being 
incorrectly mounted is not covered by warranty. 

1.  Choose a position that will allow you to see the 

OxiBOSS  Display  easily.  Fix  the  control  box  in 
position using screws at each corner of the box.

NOTE: 

Make sure that the OxiBOSS is positioned 

near enough to a power outlet and to the T-piece 
and sanitiser drum  to allow the power connecting 
and sensor cables to reach without straining.

3.  The OxiBOSS should only be powered on when the 

pool pump is running. This can be done in 3 ways :

For  USA  installations,  when  there  is  no  spare 
outlet  socket,  cut  the  110V  plug  off  the  AC/DC 
adaptor cable, and hard wire to the control system 
terminals. 

DO  NOT  SWITCH  THE  POWER  ON  UNTIL 
INSTALLATION HAS BEEN COMPLETED.

SANITISER PUMP TUBE INSTALLATION

.

Drum weight

inside sanitiser drum.

Drum Label

(e.g. Chlorine)

Ensure that your Sanitiser

Drum has the correct label 

with applicable safety 

information

Delivery tube

firmly fixed

into one way

valve in Tee.

See page 10.

Supply tube fed

through 7.0mm

(1/4") hole, drilled

into sanitiser drum lid.

Supply tube

on left side

of sanitiser

pump

Delivery tube

on right side

of sanitiser pump

FLOW DIRECTION

9

Summary of Contents for OxiBOSS

Page 1: ...d before you call us for advice Version 2 1a 19 Sep 2019 bionizer com au bionizer com Bionizer highly recommends that a pH BOSS automatic pH Controller is used together with the OxiBOSS Controller Whe...

Page 2: ...NG 17 BIONIZER CONTACT INFORMATION 20 CONTROL BOX INSTALLATION 9 MAINTENANCE 13 PUMP SQUEEZE TUBE LUBRICATION AND REPLACEMENT 15 TEE PIECE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 10 AUTO OFF BUTTON...

Page 3: ...her load would need around 4ppM of Chlorine to maintain a chemical activity of 650 mV ORP A pool that is not being used during winter with low water temperature may need 1ppM of Chlorine to maintain t...

Page 4: ...omaticsanitisercontrol Presstoscrollthroughthesixusersettingmenus Presstosavechangeswhenadjustingsettings 16x2Linealphanumeric LCD with LED backlight Presstomakeschangestousersettings Precision high q...

Page 5: ...Main OxiBOSS Display 5 ThecurrentORPofthePool The Set Point at which the OxiBOSS will maintaintheORPlevel Seepage12 The arrow is also animated whenever thedosingpumpisaddingchemical The Arrow here ind...

Page 6: ...nd using this electrical equipment includingthefollowing 5 Always power the OxiBOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the OxiBOSS and will void your warranty 5 Re...

Page 7: ...section of pipe sufficient for the Probe Injection Tee piece For 40mm 1 5 pipe where the reducing busheswillbeused cutouta7cm 2 75 section ofpipe NOTE Turn off all valves prior to fitting the T piece...

Page 8: ...rom vertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE ORP PROBE HORIZONTAL WHICH WILL RENDER THE ORP PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount...

Page 9: ...resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty 1 Choose a position that will allow you to see the OxiBOSS Display easily Fix the control box in positionusi...

Page 10: ...y by hand A tool may be used for another to 1 turn if the fitting is leaking when the pumpisrunning DO NOT OVER TIGHTEN 3 After the ORP Probe is installed in the Tee piece connect plug on the ORP Prob...

Page 11: ...water This is related tobothpoolsize andpump pipesetup In general a smaller pool would use a lower Dose Setting than a large pool However other factors can affectthis suchaspoolturnovertime 20 250 000...

Page 12: ...THE SANITISER PUMP WILL BE DISABLED AND THE OxiBOSS WILL NOT PUMP MORE SANITISER UNTIL THE ALARM HAS BEEN RESET Problem DoseSettingistoolowortoohigh Fix See page 11 for information on how to changethe...

Page 13: ...rnalpowersource pleaseensurethat the pool pump is switched off and unplugged duringtheentirecalibrationprocedure The ORP Probe should be calibrated to ensure that the readout is correct Calibration is...

Page 14: ...t into the Tee Re connect the ORP Probe to OxiBOSS when done Switchyourpoolequipmentbackon Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestar...

Page 15: ...an be pushedbackinplace Pull off the pump cover Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside MAINTENANCE Apply Silicon grease here Pull out the pump rotor a littl...

Page 16: ...her lubricated or replaced the last step is to reset the Squeeze Tube remindertozero Replacement Squeeze Tubes are supplied with new Supply and Delivery tubes pre fitted for your convenience It will b...

Page 17: ...ntactyourdistributororBionizer Faulty AC DC poweradaptor FaultyOxiBOSS mainunit ReturntoBionizerforrepair ReducetheDoseSettingbyonelevelandcheckin2days DoseSettingissettoohigh Replacesqueezetubeand or...

Page 18: ...ayed when the peristaltic dosing pump has exceeded 50 hours of operation since the last time the Squeeze Tube was lubricated or changed ThismessageisdisplayedeachtimetheOxiBOSSisswitchedon If you need...

Page 19: ...s Reduces Copper Ion loss from various environmental stressors Use a double dose of Ionlife when going away for extended holidays to help ensure that you return to a pristinepool MayextendthelifeofCop...

Page 20: ...Email relax bionizer com 16427 N Scottsdale Rd Suite 410 USA Toll Free 1 855 8 IONIZE Web bionizer com QLD 4558 Australia Web bionizer com au 1 173 Bradman Ave Phone 1800 10 62 74 Fax 61 7 5443 6700 E...

Reviews: