OxiBOSS INSTALLATION
SET THE TIMER FOR THIS OUTLET TO THE
SAME SETTING AS THE POOL PUMP OUTLET.
2. Make sure that the unit is undercover and that the
Display is not in direct sunlight as it is not covered
by warranty if it is damaged by sunlight.
2) Plug the optional AC/DC power adaptor into
one of the two mains power outlets provided on
the Bionizer unit.
4. Connect the low voltage plug to the OxiBOSS DC
Power Socket (see Page 4). Use only a genuine
Bionizer power adaptor or warranty may be void.
1) Connect the short DC to DC adaptor lead from
one of the Bionizer DC outlet sockets to the
OxiBOSS DC Power Socket.
3) When connecting to a pool control system,
connect the AC/DC adaptor to a suitable power
outlet on the control system, if available.
CONTROL BOX INSTALLATION
The control box MUST be mounted vertically, with
the cables at the bottom, in order to be weather
resistant. Any water ingress due to the unit being
incorrectly mounted is not covered by warranty.
1. Choose a position that will allow you to see the
OxiBOSS Display easily. Fix the control box in
position using screws at each corner of the box.
NOTE:
Make sure that the OxiBOSS is positioned
near enough to a power outlet and to the T-piece
and sanitiser drum to allow the power connecting
and sensor cables to reach without straining.
3. The OxiBOSS should only be powered on when the
pool pump is running. This can be done in 3 ways :
For USA installations, when there is no spare
outlet socket, cut the 110V plug off the AC/DC
adaptor cable, and hard wire to the control system
terminals.
DO NOT SWITCH THE POWER ON UNTIL
INSTALLATION HAS BEEN COMPLETED.
SANITISER PUMP TUBE INSTALLATION
.
Drum weight
inside sanitiser drum.
Drum Label
(e.g. Chlorine)
Ensure that your Sanitiser
Drum has the correct label
with applicable safety
information
Delivery tube
firmly fixed
into one way
valve in Tee.
See page 10.
Supply tube fed
through 7.0mm
(1/4") hole, drilled
into sanitiser drum lid.
Supply tube
on left side
of sanitiser
pump
Delivery tube
on right side
of sanitiser pump
FLOW DIRECTION
9